Abstract: 
This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)-100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.
Issue Date: 
1-Apr-2010
Citation: 
Brazilian Oral Research, v. 24, n. 2, p. 147-152, 2010.
Time Duration: 
147-152
Keywords: 
  • Dental alloys
  • Dental casting investment
  • Dental casting technique
  • Dental prosthesis
  • Titanium
  • biomedical and dental materials
  • phosphate
  • titanium
  • analysis of variance
  • chemistry
  • denture
  • endodontics
  • hardness
  • heat
  • materials testing
  • surface property
  • tooth crown
  • Analysis of Variance
  • Crowns
  • Dental Casting Investment
  • Dental Casting Technique
  • Dental Marginal Adaptation
  • Dental Materials
  • Hardness Tests
  • Hot Temperature
  • Materials Testing
  • Phosphates
  • Surface Properties
Source: 
http://dx.doi.org/10.1590/S1806-83242010000200004
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/71624
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.