You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/72248
Title: 
Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling
Author(s): 
Institution: 
Universidade Estadual Paulista (UNESP)
ISSN: 
1883-1958
Abstract: 
Purpose: The aim of this study was to evaluate the effect of different levels of unilateral angular misfit on preload maintenance of retention screws of single implant-supported prostheses submitted to mechanical cycling. Materials and methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n=12). The crowns presented no misfit in Group A (control group) and unilateral misfits of 50μm, 100μm and 200μm in the groups B, C and D, respectively. The crowns were attached to external hexagon implants with a titanium retention screw with torque of 30N/cm. Oblique loading of 130N at 2Hz was applied on each replica, totalizing 5×104 and 1×106cycles. Detorque values were measured initially and after each cycling period. Data were evaluated by analysis of variance and Tukey's HSD test (p<0.05). Results: All groups presented reduced initial detorque values (p< 0.05) in comparison to the insertion torque (30. ± 0.5. N/cm) and Group A (25.18. N/cm) exhibited the lowest reduction. After mechanical cycling, all groups presented detorque values from 19.5. N/cm to 22.38. N/cm and the mechanical cycling did not statistically influence the detorque values regardless the misfit level of the replicas. Conclusion: The unilateral misfit influenced the preload maintenance only before mechanical cycling. The mechanical cycling did not influence the torque reduction. © 2010 Japan Prosthodontic Society.
Issue Date: 
1-Jan-2011
Citation: 
Journal of Prosthodontic Research, v. 55, n. 1, p. 12-18, 2011.
Time Duration: 
12-18
Keywords: 
  • Dental implant
  • Implant-supported prosthesis
  • Mechanical cycling
  • Misfit
  • Preload
  • chromium derivative
  • dental alloy
  • dental care
  • denture
  • mechanical stress
  • methodology
  • prosthesis
  • tooth crown
  • tooth prosthesis
  • torque
  • Chromium Alloys
  • Crowns
  • Dental Abutments
  • Dental Alloys
  • Dental Prosthesis Design
  • Dental Prosthesis Retention
  • Dental Prosthesis, Implant-Supported
  • Dental Stress Analysis
  • Prosthesis Fitting
  • Stress, Mechanical
  • Torque
Source: 
http://dx.doi.org/10.1016/j.jpor.2010.05.002
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/72248
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.