You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/74126
Title: 
Traditional and novel methods for occlusal caries detection: Performance on primary teeth
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • Cruzeiro do sul University (UNICSUL)
  • Universidade Federal do Rio Grande do Sul (UFRGS)
  • University of Bern
  • Faculdade de Odontologia de Araraquara
ISSN: 
  • 0268-8921
  • 1435-604X
Abstract: 
This study aimed to assess the performance of International Caries Detection and Assessment System (ICDAS), radiographic examination, and fluorescence-based methods for detecting occlusal caries in primary teeth. One occlusal site on each of 79 primary molars was assessed twice by two examiners using ICDAS, bitewing radiography (BW), DIAGNOdent 2095 (LF), DIAGNOdent 2190 (LFpen), and VistaProof fluorescence camera (FC). The teeth were histologically prepared and assessed for caries extent. Optimal cutoff limits were calculated for LF, LFpen, and FC. At the D 1 threshold (enamel and dentin lesions), ICDAS and FC presented higher sensitivity values (0.75 and 0.73, respectively), while BW showed higher specificity (1.00). At the D 2 threshold (inner enamel and dentin lesions), ICDAS presented higher sensitivity (0.83) and statistically significantly lower specificity (0.70). At the D 3 threshold (dentin lesions), LFpen and FC showed higher sensitivity (1.00 and 0.91, respectively), while higher specificity was presented by FC (0.95), ICDAS (0.94), BW (0.94), and LF (0.92). The area under the receiver operating characteristic (ROC) curve (Az) varied from 0.780 (BW) to 0.941 (LF). Spearman correlation coefficients with histology were 0.72 (ICDAS), 0.64 (BW), 0.71 (LF), 0.65 (LFpen), and 0.74 (FC). Inter- and intraexaminer intraclass correlation values varied from 0.772 to 0.963 and unweighted kappa values ranged from 0.462 to 0.750. In conclusion, ICDAS and FC exhibited better accuracy in detecting enamel and dentin caries lesions, whereas ICDAS, LF, LFpen, and FC were more appropriate for detecting dentin lesions on occlusal surfaces in primary teeth, with no statistically significant difference among them. All methods presented good to excellent reproducibility. © 2012 Springer-Verlag London Ltd.
Issue Date: 
1-Jan-2013
Citation: 
Lasers in Medical Science, v. 28, n. 1, p. 287-295, 2013.
Time Duration: 
287-295
Keywords: 
  • Caries detection
  • Fluorescence
  • Occlusal caries
  • Primary teeth
  • Radiography
  • Visual examination
  • accuracy
  • controlled study
  • deciduous tooth
  • dental caries
  • dental device
  • dentin
  • enamel
  • fluorescence
  • histology
  • human
  • human tissue
  • in vitro study
  • intermethod comparison
  • molar tooth
  • priority journal
  • receiver operating characteristic
  • reproducibility
  • sensitivity and specificity
  • tooth radiography
  • Area Under Curve
  • Dental Caries
  • Dental Caries Activity Tests
  • Humans
  • Lasers
  • Molar
  • Radiography, Bitewing
  • ROC Curve
  • Sensitivity and Specificity
  • Tooth, Deciduous
Source: 
http://dx.doi.org/10.1007/s10103-012-1154-8
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/74126
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.