You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/74374
Title: 
Voltammetric determination of ethyl acetate in ethanol fuel using a Fe 3+/Nafion®-coated glassy carbon electrode
Author(s): 
Institution: 
  • Universidade Estadual Paulista (UNESP)
  • Universidade Federal de Uberlândia (UFU)
  • Universidade de São Paulo (USP)
ISSN: 
0016-2361
Abstract: 
A voltammetric method for the determination of ethyl acetate in ethanol fuel using a Fe3+/Nafion®-coated glassy carbon electrode (GCE) is proposed. The ethyl acetate present in the ethanol fuel was previously converted to acetohydroxamic acid via pretreatment with hydroxylamine chloride. The acetohydroxamic acid promptly reacted with the iron (III) present in the film, producing iron (III) acetohydroxamate, which presents a well-defined voltammetric peak current at -0.02 V. Optimization of the voltammetric parameters for the cyclic, linear sweep, square wave, and differential pulse modalities was carried out for this chemically-modified electrode. Square wave voltammetry afforded the best response for acetohydroxamic acid detection. The analytical curve for this species was linear from 9 to 100 μmol L 1 according to the following equation: ip (μA) = 0.27 + 2.55Cacetohydroxamic acid (μmol L 1), with linear correlation coefficient equal to 0.993. The technique presented limit of detection equal to 5.3 μmol L 1 and quantification limit of 17.6 μmol L 1. The proposed method was compared to the official method of ethyl acetate analysis (Gas Chromatography), and a satisfactory correlation was found between these techniques. © 2012 Elsevier Ltd. All rights reserved.
Issue Date: 
14-Jan-2013
Citation: 
Fuel, v. 106, p. 837-842.
Time Duration: 
837-842
Keywords: 
  • Chemically modified electrode
  • Ethanol fuel
  • Ethyl acetate
  • Quality control
  • Voltammetry
  • Acetohydroxamic acids
  • Ethyl acetates
  • Glassy carbon electrodes
  • Linear correlation coefficient
  • Square wave voltammetry
  • Voltammetric determination
  • Voltammetric parameters
  • Chlorine compounds
  • Ethanol fuels
  • Gas chromatography
  • Glass
  • Glass membrane electrodes
Source: 
http://dx.doi.org/10.1016/j.fuel.2012.10.045
URI: 
Access Rights: 
Acesso restrito
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/74374