You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/87289
Title: 
Análise do princípio centrando do método pilates e de indicadores de resistência e estabilidade da coluna lombar
Author(s): 
Marques, Nise Ribeiro
Institution: 
Universidade Estadual Paulista (UNESP)
Sponsorship: 
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Abstract: 
  • A etiologia da dor lombar inespecífica está relacionada com erros na ativação muscular, tais como o aumento no tempo de resposta dos músculos, frente a uma perturbação, e a diminuição da co-contração antagonista, que geram diminuição na estabilidade. Nesse sentido, o presente estudo teve por objetivo analisar indicadores EMG de estabilidade da coluna lombar em indivíduos saudáveis e com dor lombar não específica. Participaram do estudo 16 voluntários do gênero feminino, fisicamente ativas, na faixa etária de 18-25 anos, recrutadas em uma população universitária, que foram divididas em dois grupos, grupo com dor lombar (GDL) e grupo controle (GC). Foram coletados os sinais EMG dos músculos reto abdominal (RA), oblíquo interno (OI), multifido (MU) e iliocostal lombar (IL) durante o teste de equilíbrio do tronco, realizado com em extensão isométrica do tronco (carga de 10% peso corporal), por um período aleatório até o acionamento de um sistema mecânico, que retirava a carga e promovia a perturbação do tronco. A análise do sinal EMG foi realizada no domínio do tempo, para o cálculo da amplitude do sinal, em uma janela de 200 ms antes e após a perturbação. Assim, foi calculada a razão entre os músculo RA+OI/MU+IL. Para a determinação do tempo de reação EMG foi utilizado o método de correlação cruzada. Houve uma tendência há maior variabilidade entre a primeira e a terceira tentativas para os valores de tempo de reação EMG e de razão antes e após a perturbação no GDL. Ccontudo, não houve diferença significativa entre os grupos ou entre as tentativas. Portanto, embora a ausência de diferenças significativas entre os grupos, a tendência a maior variabilidade destes indicadores entre a primeira e a terceira tentativas no GDL pode representar um menor controle motor desta região
  • The etiology of nonspecific low back pain is related to errors in muscle activation, such as the increase in response time of the muscles in front of a disturbance, and decreased antagonist co-contraction, which generates a impaired spine stability. In line of this, the present study had the goal to analyze EMG indicators of lumbar spine stability in healthy and non-specific low back pain individuals. The participants were 16 female volunteers who are physically fit, aged 18-25 years, which were recruited from a university setting, divided in two groups, low back pain group(LBPG) and control group (CG). EMG signals was collected on the muscles: rectus abdominis (RA), internal oblique (IO), multifidus (MU) and iliocostalis lumborum (IL) during the trunk balance test, which was performed by an isometric trunk extension (load of 10% of body mass) for a random time until was fired a mechanical system, which removed the load and promoted the disturbance at the trunk. The EMG signal analysis was performed in the time domain, to calculate the signal amplitude in a window of 200 ms before and after the disturbance. Thus, was calculated the ratio of muscle RA+IO/MU+IL. To determine the reaction time was used EMG cross-correlation method. There was a tendency for greater variability between the first and third trials for the values of reaction time and EMG ratio before and after a disturbance in the LBPG. However, no significant difference between the groups or trials were found. So, although the absence of significant differences between groups, a trend of greater variability in these indicators between the first and third attempts in the LBPG may represent a reduced motor control of this region
Issue Date: 
18-Mar-2011
Citation: 
MARQUES, Nise Ribeiro. Análise do princípio centrando do método pilates e de indicadores de resistência e estabilidade da coluna lombar. 2011. 113 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Ciências e Tecnologia, 2011.
Time Duration: 
113 f. : il.
Publisher: 
Universidade Estadual Paulista (UNESP)
Keywords: 
  • Fisioterapia
  • Eletromiografia
  • Dor lombar
  • Biomecânica
  • Electromyography
  • Low back pain
  • Physiotherapy
  • Biomechanics
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/87289
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.