You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/89033
Title: 
Osteossíntese de tíbia com uso de fixador esquelético externo conectado ao pino intramedular tie-in em cães
Author(s): 
Dias, Luis Gustavo Gosuen Gonçalves
Institution: 
Universidade Estadual Paulista (UNESP)
Sponsorship: 
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Abstract: 
  • A incidência de fratura de tíbia em cães representa 21% das que ocorrem nos ossos longos. Vários métodos são utilizados nas osteossínteses deste osso, tais como: pinos intramedulares; fixadores esqueléticos externos; placas ósseas e; associações entre eles. O método usado foi uma modificação da configuração denominada tie-in, na qual um PIM é conectado externamente a pinos de Schanz ou parafusos de aço inoxidável fixados com metil-metacrilato. O PIM é introduzido através de um orifício confeccionado na face medial da tíbia, próximo à crista tibia!. A configuração foi utilizada em 21 cães com fratura de tíbia atendidos no Hospital Veterinário do Câmpus da UNESP de Jaboticabal-SP. Os animais foram avaliados clínica e radiograficamente, no período pré e pós-operatório imediato e a cada 30 dias, até completar quatro meses. Os animais recuperaram, clinicamente, a função do membro no período médio de 11 dias após a cirurgia. Nove animais tiveram a configuração dinamizada, por meio da desconexão do PIM; remoção do PIM ou dos implantes de fixação e retirada dos implantes de fixação e manutenção do PIM. Radiograficamente verificou-se consolidação óssea em média de 76 dias de pós operatório, e apenas um animal apresentou não-união. A configuração tie-in mostrou se eficaz como método de osteossíntese em fraturas tibiais de cães.
  • The incidence of tibial fractures in dogs assumes 21 % of ali fractures that occur in long bones. Several methods are used in the osteosynthesis, of these fractures like external skeletal fixator, bone plates and associated techniques. The aim of this study is to describe the method and perform a radiographic and clinical evaluation of a group of 21 dogs with tibial fractures from the veterinary teaching hospital of the UNESP SÃO PAULO STATE UNIVERSITY- CAMPUS OF JABOTICABAL. The used method was a modification of the termed tie-in configuration, in that an IMP was connected externally with Schanz pins or stainless steel screws fixed together with methylmethacrylat. The pin was applied through hole on the medial tibia near the tibial crest. Clinical and radiographic evaluations were performed in pre-and post-operatory period and at 30, 60, 90 and 120 days. Animais recovered the function of the affected limb in a mean period of 11 days afier the surgery. Nine dogs underwent dynamization through: a) IMP disconnection, b) IMP or, c) fixation pins takeout and d) fixation pins takeout and maintenance of the IMP. Radiographicaly, the fracture union occurred in 20 dogs, in a mean period of 76 days; non-union was observed in only one dog. T~erefore, the tie-in modificated frame configuration showed efficacy as a method of osteosynthesis in tibial fractures of dogs.
Issue Date: 
28-Jun-2006
Citation: 
DIAS, Luis Gustavo Gosuen Gonçalves. Osteossíntese de tíbia com uso de fixador esquelético externo conectado ao pino intramedular tie-in em cães. 2006. xiv, 79 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Ciências Agrárias e Veterinárias, 2006.
Time Duration: 
xiv, 79 f. : il.
Publisher: 
Universidade Estadual Paulista (UNESP)
Keywords: 
  • Cirurgia
  • Ortopedia
  • Cão
  • Fraturas - Fixação interna
  • Ortopedics
  • Surgery
  • Fracture
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/89033
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.