You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/89112
Title: 
Dopperfluxometria e avaliação morfométrica da veia porta em cães hígidos diferentes pesos corpóreos
Author(s): 
Sartor, Raquel
Institution: 
Universidade Estadual Paulista (UNESP)
Sponsorship: 
Universidade Estadual Paulista (UNESP)
Abstract: 
  • A perfusão total hepática e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasias e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler, mostrou-se um método de grande auxílio, principalmente na avaliação da hemodinâmica portal. Tal avaliação é feita pela mensuração da área, velocidade média, volume de fluxo sangüíneo e pelo índice de congestão portal. Este estudo teve como objetivos mensurar os diâmetros e as áreas da veia porta, da veia cava caudal e da aorta abdominal, e efetuar a avaliação dopplerfluxométrica da veia porta de cães hígidos divididos em três grupos conforme o peso corporal, (Grupo A: 10kg; Grupo B: de 10,1 a 20,0kg; Grupo C: 20,1kg), e avaliar se estas variáveis são influenciadas pelo peso do animal. Os diâmetros e as áreas da veia porta, da veia cava caudal e aorta abdominal foram significativamente menores para os cães do Grupo A em relação aos demais grupos e, os cães dos Grupos B e C tiveram resultados semelhantes entre si. Na dopplerfluxometria da veia porta, a velocidade média de fluxo foi semelhante para os três grupos avaliados, não variando com o peso do animal. O volume de fluxo e o índice de congestão portal foram respectivamente maior e menor para o Grupo A em relação aos demais, os quais obtiveram resultados semelhantes entre si.
  • Total hepatic perfusion through the portal system and hepatic artery, as well as its respective average contributions, can be affected by several hepatic processes such as diffuse liver disease, neoplasm and intrahepatic shunt. Blood flow exams of liver vessels using Doppler ultrasonography has been a viable non-invasive diagnostic method helpful in portal hemodynamic evaluation. Portal hemodynamics is assessed by measuring the area, mean velocity, flow volume and congestion index of the portal vein. The aims of this study were to measure the diameter and area of portal vein, caudal vena cava and abdominal aorta; to analyze, through Doppler flowmetry, the portal vein of healthy dogs, which were divided into three groups according to body weight (Group A: 10 kg; Group B: 10.1–20.0 kg; Group C: 20.1 kg); and to assess whether these data are influenced by the animal weight. The diameter and area of the evaluated vessels were significantly larger in Group A, relative to the other groups, and similar between Groups B and C. The mean velocity of portal vein flow was similar among groups and did not vary with the animal weight. Group A had greater flow volume and lower congestion index of portal system, relative to the other groups, which had similar results.
Issue Date: 
27-Jun-2008
Citation: 
SARTOR, Raquel. Dopperfluxometria e avaliação morfométrica da veia porta em cães hígidos diferentes pesos corpóreos. 2008. 85 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Medicina Veterinária e Zootecnia, 2008.
Time Duration: 
85 f.
Publisher: 
Universidade Estadual Paulista (UNESP)
Keywords: 
  • Cão - Doenças - Diagnóstico
  • Doppler, Ultrassonografia
  • Ultrassonografia
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/89112
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.