You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/95390
Title: 
Emprego da tomografia computadorizada de feixe cônico na análise de alterações periapicais de origem endodôntica in vivo, e na instrumentação de canais radiculares in vitro
Author(s): 
Nakazone, Paula Aparecida
Institution: 
Universidade Estadual Paulista (UNESP)
Sponsorship: 
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
  • Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Abstract: 
  • A radiografia periapical convencional é o método mais utilizado na detecção e controle de lesões periapicais após o tratamento endodôntico. Atualmente, a tomografia computadorizada de feixe cônico (TCFC) tem sido amplamente utilizada, não apenas para uso clínico como também para fins de pesquisa. Diferentes metodologias têm sido descritas com o propósito de avaliar a instrumentação dos canais radiculares. Em associação aos avanços nos softwares de imagem, a TCFC tem se mostrado importante no desenvolvimento de métodos de avaliação, especialmente na área de Endodontia, como por exemplo, para avaliações do preparo do canal radicular e do reparo periapical após o tratamento endodôntico. No entanto, a fim de se obter métodos de avaliação comparativa mais criteriosos, e que possibilitem o uso da técnica de subtração digital (SD), torna-se importante a padronização das imagens. Na primeira parte deste estudo foi realizada a avaliação comparativa da mensuração da lesão periapical por dois métodos: a tomografia computadorizada com aquisição volumétrica (de feixe cônico) e a radiografia periapical digitalizada, nos períodos final do tratamento endodôntico (T0) e três meses de proservação (T1). Os dados obtidos para as mensurações radiográficas e tomográficas foram submetidas aos testes T Pareado e ANOVA, com nível de significância de 5%. Os resultados mostraram que as medidas obtidas nos métodos, radiográfico e tomográfico, foram semelhantes em ambos os períodos avaliados, demonstrando redução significativa da área de lesão aos três meses de proservação (p<0,05) e de forma semelhante nos dois métodos de avaliação (p>0,05). A partir dos resultados pode-se concluir que os métodos de avaliação por imagem, radiográfico e tomográfico, evidenciaram a regressão de lesões periapicais, três meses após o tratamento endodôntico...
  • Periapical conventional radiography is the most used method in detection and control of periapical lesions after endodontic treatment. Actually, cone beam computed tomography (CBCT) has been widely used, not only for clinical use as also for research ends. Different methods have been described with the proposal of evaluate root canal instrumentation. In association to image software development CBCT has revealed to be important in the evaluation methods development, especially in Endodontics, for example, in the evaluation of root canal preparation and in the evaluation of periapical repair after endodontic treatment. However, in order to obtain more criterious comparative evaluation methods, which enable the use of radiographic subtraction technique, images standardization becomes important. In the first part of this study, a comparative evaluation of periapical lesion measurement was realized by two methods: volumetric acquisition computed tomography (cone beam) and periapical digitalized radiography, in the periods at the end of endodontic treatment (T0) and at three months of follow up (T1). Data obtained were submitted to T and ANOVA tests, with 5% of significance. The results showed that the measurements obtained in radiographic and tomographic methods were similar in both of evaluated periods demonstrating significant decrease of lesion area after three months (p<0,05) and similarly in these two evaluation methods. From the results is concluded that radiographic and tomographic evaluation methods showed the regression of periapical lesions, at three months of follow up period (T1), providing similar measurements. In the following parts of this study, standardization techniques for images obtained from volumetric acquisition computed tomography or cone beam (CBCT) were proposed. Both the techniques used the Xoran software (Xoran Technologies – Ann Arbor – Michigan/USA)... (Complete abstract click electronic access below)
Issue Date: 
26-Mar-2010
Citation: 
NAKAZONE, Paula Aparecida. Emprego da tomografia computadorizada de feixe cônico na análise de alterações periapicais de origem endodôntica in vivo, e na instrumentação de canais radiculares in vitro. 2010. 125 f. Dissertação (mestrado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araraquara, 2010.
Time Duration: 
125 f. : il. color.
Publisher: 
Universidade Estadual Paulista (UNESP)
Keywords: 
  • Tomografia
  • Endodontia
  • Radiografia dentária
  • Reabsorção óssea
  • Tomography
  • Dental radiography
  • Endodontic
  • Bone resorption
URI: 
Access Rights: 
Acesso aberto
Type: 
outro
Source:
http://repositorio.unesp.br/handle/11449/95390
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.