You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/100434
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorDenadai, Benedito Sérgio [UNESP]-
dc.contributor.authorCaputo, Fabrizio-
dc.date.accessioned2014-06-11T19:30:53Z-
dc.date.accessioned2016-10-25T19:25:33Z-
dc.date.available2014-06-11T19:30:53Z-
dc.date.available2016-10-25T19:25:33Z-
dc.date.issued2006-08-11-
dc.identifier.citationCAPUTO, Fabrizio. Determinação da maior intensidade de esforço onde o consumo máximo de oxigênio é atingido durante o ciclismo: influência do estado e especificidade do treinamento aeróbio. 2006. xiv, 80 f. Tese (doutorado) - Universidade Estadual Paulista, Instituto de Biociências, 2006.-
dc.identifier.urihttp://hdl.handle.net/11449/100434-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/100434-
dc.description.abstractOs principais objetivos deste estudo foram: 1) Determinar e comparar em cicloergômetro a cinética do consumo de oxigênio (V02) em intensidades do domínio severo (constante de tempo - Tais), e a maior intensidade (Isup) e o menor tempo de exercício (Tsup) onde o VO2max pode ser alcançado, em ciclistas (dc), corredores (COR) e indivíduos sem treinamento (ST); 2) Verificar a validade de um modelo para estimar indiretamente a 1sup (lsup') e Tp (Tsup'). Onze COR, quinze dc e dez ST realizaram em dias diferentes os seguintes testes: 1) teste incremental para determinação do VO2max e da intensidade correspondente ao VO2max (lVO2max); 2) Testes de cargas constantes realizados aieatoriamente a 95. 100 e 1 1O%lVO2max, para determinar o tempo de exaustão (Tlim), Tau lsup' e Tsup'; 3) 2 a 4 testes de carga constante onde a intensidade foi aumentada ou diminuída até que o VO2max não pudesse ser atingido para determinação da lp e TSU. O tempo para atingir o VO2max (TAVO2max) foi calculado através de um modelo de uste mono-exponencial assumindo um valor de 4,6 vezes o Tau. O Tsup' foi estimado individualmente através da regressão linear entre os TAVO2max e seus respectivos Tlim. A l' foi estimada através do modelo hiperbólico de potência critica A ISUP foi considerada como a maior intensidade onde a média do V02 de três valores consecutivos de 5 s foi maior ou igual à média do VO2max obtidos nos testes incrementa] e de carga constante menos um desvio padrão. O Tsup foi considerado como o Tlim associado à ISLP. Os valores de VO2max (mlkg'-miW') (ST = 42,2 l 4,0; COR 54,6 l 5,5; CIC = 64,5 l 6,4) foram significativamente diferentes entre os grupos. O TSUP e o Tau (todas as intensidades) foram semelhantes entre COR e ST e ambos maiores em relação ao CIC.pt
dc.description.abstractThe main objectives of the present study were: 1) To determine and to compare in cycle ergometer the oxygen uptake (V02) kinetics in the severe intensity domam (time constam - Tau), and the highest intensity (Isup) and the shortest exercise time (Tsup) which VO2max can be elicitcd in cyclists (dc), runners (COR) and untrained subjects (ST); 2) to evaluate the validity of a model for estimating the 1sup (lsup) and Tsup (Tsup'). Fifleen CJC, eleven COR and ten ST performed in different days the following tests: 1) incrementa! tests for determination of VO2max and lhe intensity corresponding at VO2max (IVO2max); 2) fatigiing constam power tests at 95, 100 e 110% !VO2max lo determine the time to exhausúon (TIim), Tau, 1sup' and Tsp'. 3) 2 to 4 fatiguing constant power tests to determine 1sup e lhe power output was decreased or increased uniu VO2max can not be elicited. The time lo achieve VO2max (TAVO2max) was calculated by a monoexponentia! fit where was assumed a fixed value of 4,6 limes Tau. Linear regression techniques were used to describe the relalionship between lhe TAVO2max and Thm lo estimate indirectly Tsup'. lsup' was calcu!ated using the critical power model. Ip was assumed to be the highest intensity where lhe 5 s V02 values determined from rolling averages of 5 s samples was equai or higber than the average of VO2max obtained in lhe incrementa] and constam power tesls minus one standard deviation. Tsup was lhe TIjm associated with lsup. VO2max values (rnlKg1min') (ST = 422 l 40; COR 54.6 l 5.5; CIC = 64.5 l 64) were significanl!y differenl among lhe grcups. No significanl differences were found in Tp and Tau (ali exercises intensities) between COR and ST, however both groups showed higher values compared to dc in.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extentxiv, 80 f. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectCiclismopt
dc.subjectConsumo de oxigêniopt
dc.subjectTreinamento aeróbiopt
dc.subjectCorredorespt
dc.subjectRunnersen
dc.subjectAerobic trainingen
dc.subjectOxygen uptakeen
dc.subjectCyclingen
dc.titleDeterminação da maior intensidade de esforço onde o consumo máximo de oxigênio é atingido durante o ciclismo: influência do estado e especificidade do treinamento aeróbiopt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filecaputo_f_dr_rcla.pdf-
dc.identifier.aleph000471811-
dc.identifier.capes33004137062P0-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.