Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/100850
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Turco, José Eduardo Pitelli [UNESP] | - |
dc.contributor.author | Vescove, Humberto Vinicius | - |
dc.date.accessioned | 2014-06-11T19:31:02Z | - |
dc.date.accessioned | 2016-10-25T19:26:26Z | - |
dc.date.available | 2014-06-11T19:31:02Z | - |
dc.date.available | 2016-10-25T19:26:26Z | - |
dc.date.issued | 2009-02-06 | - |
dc.identifier.citation | VESCOVE, Humberto Vinicius. Consumo e custo de energia elétrica na cultura de citros irrigada por gotejamento e microaspersão, com três lâminas de água. 2009. vi, 50 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Ciências Agrárias e Veterinárias, 2009. | - |
dc.identifier.uri | http://hdl.handle.net/11449/100850 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/100850 | - |
dc.description.abstract | O objetivo deste trabalho foi analisar o consumo, o custo de energia elétrica e resultado econômico em citros (Citrus sinensis) irrigado. Os tratamentos constaram de sistemas de irrigação do tipo gotejamento, com uma e duas linhas laterais de distribuição de água, microaspersão e um tratamento sem irrigação. Para cada sistema foram utilizadas três lâminas de água; 100%, 75% e 50% da Etc (evapotranspiração da cultura). Foi estudado o custo da energia elétrica para dois grupos tarifários, Grupo A e Grupo B. No grupo A foram determinados os dispêndios com a energia para tarifas Estrutura Binômia Convencional e Horo-Sazonal (verde e azul), além, da tarifa especial para irrigante noturno. Os preços de demanda e kWh dos sistemas tarifários foram obtidos no site CPFL (Companhia Paulista de Força e Luz). A menor relação entre o consumo de energia elétrica por ha (kWh.ha-1) e a produtividade (t) foi obtida nos tratamentos irrigados com 50% da Etc. O sistema tarifário horosazonal verde/azul Grupo A irrigante noturno teve o menor custo de energia. Os tratamentos irrigados com lâmina de 50% apresentaram maiores produtividade em relação à lâmina de 100% da Etc. O maior retorno econômico ocorreu nos tratamentos irrigados com 50% da Etc. | pt |
dc.description.abstract | The objective of this work is to analyze the consumption, the electric energy cost, and the economic results in irrigated citros (Citrus sinensis). The procedures used consisted of a dripping equipment, with one and two lateral lines of water distribution, a micro sprinkler as well as a treatment without irrigation. For each system of irrigation, three water depths have been used; 100%, 75% and 50% of Etc (citrus evapotranspiration). The electric energy cost was studied for two tariff groups, Group A and Group B. For the Group A it was determined the expenses with the energy for the tariffs Binômia Structure Convencional and Horo-Sazonal (green and blue), besides the special tariff for nocturnal irrigation. The prices of the kWh tariff were obtained from the CPFL site ( power company of Sao Paulo, Brazil). The best relation between the consumption of electric energy (kWh.ha-1) and the productivity (t.ha-1) occurred when the irrigation is done with 50% of the Etc. The tariff system Horo-Sazonal green and blue of the Group A, with nocturnal irrigation, showed the smaller energy cost. The irrigated treatments with depth of 50% have presented higher productivity than those of 100% of Etc. Higher economical returns are achieved when the treatments irrigated with 50% of the Etc are chosen. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | vi, 50 f. : il. | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Irrigação | pt |
dc.subject | Cítricos | pt |
dc.subject | Lâminas de irrigação | pt |
dc.subject | Sistemas de irrigação | pt |
dc.subject | Sistemas tarifários de energia | pt |
dc.subject | Irrigation depths | en |
dc.subject | Systems irrigation | en |
dc.subject | Tariff systems of energy | en |
dc.title | Consumo e custo de energia elétrica na cultura de citros irrigada por gotejamento e microaspersão, com três lâminas de água | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | vescove_hv_dr_jabo.pdf | - |
dc.identifier.aleph | 000596003 | - |
dc.identifier.capes | 33004102071P2 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.