You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/101147
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorNunes, Newton [UNESP]-
dc.contributor.authorBatista, Priscila Andrea Costa dos Santos-
dc.date.accessioned2014-06-11T19:31:09Z-
dc.date.accessioned2016-10-25T19:27:05Z-
dc.date.available2014-06-11T19:31:09Z-
dc.date.available2016-10-25T19:27:05Z-
dc.date.issued2011-06-20-
dc.identifier.citationBATISTA, Priscila Andrea Costa dos Santos. Estudo comparativo entre as ventilações espontânea, mandatória intermitente sincronizada, pressão de suporte e volume garantido e suporte pressórico, em coelhos anestesiados com propofol e induzidos à hipovolemia aguda. 2011. xxviii, 119 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Ciências Agrárias e Veterinárias, 2011.-
dc.identifier.urihttp://hdl.handle.net/11449/101147-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/101147-
dc.description.abstractAvaliaram-se os efeitos das ventilações espontânea, mandatória intermitente sincronizada (SIMV), pressão de suporte e volume garantido (VAPSV) e suporte pressórico (VPS) sobre as variáveis hemogasométricas, cardiovasculares e da dinâmica respiratória em coelhos anestesiados com infusão contínua de propofol e submetidos à hipovolemia aguda. Para tal, foram utilizados 40 coelhos, da raça Nova Zelândia, os quais foram distribuídos em quatro grupos, sendo denominados GE (ventilação espontânea), GM (SIMV), GP (VPS) e GV (VAPSV). Na medicação préanestésica foi administrado cetamina (15 mg/kg) e xilazina (1 mg/kg) pela via intramuscular. O propofol foi empregado na indução (8mg/kg) e na manutenção anestésica (0,5 mg/kg/min). Decorridos 40 minutos da indução, os animais foram induzidos à hipovolemia por meio da retirada de sangue arterial (12 mL/kg). Os parâmetros foram mensurados 40 minutos após a indução anestésica (M0), seguido de novas mensurações a cada dez minutos depois da hipovolemia (de M1a M6). O método estatístico utilizado foi o quadrado mínimo, utilizando o programa computacional SAS. Em relação às variáveis cardiovasculares, as médias de débito cardíaco no GE, GP e GM foram maiores que as no GV. Quanto à hemogasometria, a pressão parcial de oxigênio no sangue arterial (PaO2) foi maior no GV do que no GE e GP. Em relação às variáveis respiratórias, os valores da pressão alveolar de oxigênio (PAO2), diferença alvéolo-arterial de oxigênio (AaDO2), espaço morto fisiológico (Vdfis) e espaço morto alveolar (Vdalv) no GE foram maiores do que no GM e GV . Enquanto, as médias do conteúdo arterial de oxigênio (CaO2), diferença entre a tensão de o dióxido de carbono alveolar e o expirado [P(a-ET)CO2], volume corrente (Vt) e tempo inspiratório (Tinsp), no GE foram menores do que no ao GV e GM...pt
dc.description.abstractThe effects of spontaneous ventilation, pressure support ventilation (VPS), synchronized intermittent mandatory ventilation (SIMV) and ventilation with pressure support and volume assured (VAPSV) on cardiovascular, blood-gas and respiratory dynamic variables, in rabbits anesthetized with continuous infusion of propofol and underwent acute hypovolemia, were evaluated. Forty New Zealand rabbits were randomly assigned into four groups, namely: GE (spontaneous ventilation), GM (SIMV), GP (VPS) and GV (VAPSV). In premedication were administered ketamine (15 mg/kg) and xylazine (1 mg/kg) intramuscularly. Propofol was used in induction (8 mg/kg) and anesthesia maintenance (0.5 mg/kg/min). After 40 minutes, the rabbits were induced to hypovolemia by withdrawing arterial blood (12 ml/kg). The parameters were measured 40 minutes after anesthetic induction (M0) and, then at 10-minute intervals after hipovolemia induction (from M1 to M6). Numeric data were submitted to the least-squares using the SAS program. In the hemodynamic parameters, means of cardiac output in GP, GE and GM were higher than in GV. About blood-gas parameters, arterial partial pressure of oxygen (PaO2) was bigger in GV than in GE and GP. The arterial hemoglobin saturation (SaO2) was lower in GP than in GV. Regarding respiratory variables, the values of alveolar oxygen partial pressure (PAO2), alveolar-arterial oxygen gradient (AaDO2), physiological dead space (Vdfis), and alveolar dead space (Vdalv) in GE were bigger than in GM, GV and GP. While, means of arterial oxygen content (CaO2), alveolar-arterial carbon dioxide gradient [P(a-ET)CO2], tidal volume (Vt) and inspiratory time (Tinsp), in GE were lower than in GV,GM and GP. The peak inspiratory pressure (PIP) was higher compared to the GV and GM, work of breathing was higher compared to the GV to GV ... (Complete abstract click electronic access below)en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extentxxviii, 119 f. : gráfs., tabs.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectCoelhopt
dc.subjectAnestesia intravenosapt
dc.subjectHipovolemiapt
dc.subjectVentilação mecânicapt
dc.subjectRabbiten
dc.subjectTotal intravenous anesthesiaen
dc.subjecthypovolemiaen
dc.subjectMechanical ventilationen
dc.titleEstudo comparativo entre as ventilações espontânea, mandatória intermitente sincronizada, pressão de suporte e volume garantido e suporte pressórico, em coelhos anestesiados com propofol e induzidos à hipovolemia agudapt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filebatista_pacs_dr_jabo.pdf-
dc.identifier.aleph000674905-
dc.identifier.capes33004102069P8-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.