You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/101844
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorLeopoldo, Paulo Rodolfo [UNESP]-
dc.contributor.authorZuccari, Maria Lúcia-
dc.date.accessioned2014-06-11T19:31:37Z-
dc.date.accessioned2016-10-25T19:28:38Z-
dc.date.available2014-06-11T19:31:37Z-
dc.date.available2016-10-25T19:28:38Z-
dc.date.issued1996-06-
dc.identifier.citationZUCCARI, Maria Lúcia. A digestão pelo calor de diluição e a determinação da demanda química de oxigênio (DQO) em águas e efluentes. 1996. vii, 89 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Ciências Agronômicas, 1996.-
dc.identifier.urihttp://hdl.handle.net/11449/101844-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/101844-
dc.description.abstractCom o objetivo de tornar mais ágil e simples a rotina da determinação da demanda química de oxigênio(DQO) em águas e efluentes, estudou-se a colorimetria da mesma, principalmente o uso do calor de diluição dos reagentes como fonte de energia para a reação de oxidação/redução em que tal determinação se fundamenta. Assim, aspectos físico-químicos dos métodos colorimétricos foram abordados para definição dos parâmetros experimentais mais adequados à determinação: espectro de absorção do sistema crômio(III)/dicromato para definição do melhor comprimento de onda para as medidas; concentração de ácido sulfúrico e quantidade de dicromato necessárias para máxima resposta da reação; tempo para ocorrência da reação e tempo de estabilidade do sistema colorido formado; interferentes do método, destacando-se o efeito negativo do íon cloreto, contornado classicamente através do mercúrio( II); faixa ótima de concentração de DQO para a curva padrão ou de referência(e conseqüentes medidas das amostras), estudada pela técnica de Ringbom. Na aplicação do método estudado à determinação da DQO em diferentes amostras de água e efluentes, verificouse que em alguns casos é insuficiente a energia somente do calor de diluição dos reagentes para se completar a reação fundamental de oxidação-redução inerente ao método... .pt
dc.description.abstractColorimetry of the COD - Chemical Oxygen Demand in wastewaters was studied to make its determination easier. The author studied the use of exothermic heat produced the addition of reagents as a source of energy for the oxidation/ reduction reaction, in which the determination is based. Then, physio-chemical aspects of colorimetric methods were analyzed to define the appropriate experimental parameters for determination the following: the absorption spectrum of chromium(III)/dichromate system to obtain the suitable wave lenght for the analysis; concentration of sulphuric acid and the quantity of dichromate needed to maximise the reaction; the reaction time and stability of the colored system; interference such as that caused by the negative effect of chloride ion, usually decreased by mercury(II); a suitable range of COD concentrations to obtain the standard or reference curve (and sample measures) studied by technique of Ringbom. Upon application of the method studied for the COD determination in different wastewaters, the author observed that, in some cases, the exothermic heat produced on... (Complete abstract, click electronic address below).en
dc.format.extentvii, 89 f. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectAgua - Analisept
dc.titleA digestão pelo calor de diluição e a determinação da demanda química de oxigênio (DQO) em águas e efluentespt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filezuccari_ml_dr_botfca.pdf-
dc.identifier.aleph000149022-
dc.identifier.capes33004064021P7-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.