Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/105690
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Rosa, André Henrique [UNESP] | - |
dc.contributor.advisor | Menegário, Amauri Antônio [UNESP] | - |
dc.contributor.author | Tonello, Paulo Sergio | - |
dc.date.accessioned | 2014-06-11T19:35:06Z | - |
dc.date.accessioned | 2016-10-25T19:37:22Z | - |
dc.date.available | 2014-06-11T19:35:06Z | - |
dc.date.available | 2016-10-25T19:37:22Z | - |
dc.date.issued | 2009-04-14 | - |
dc.identifier.citation | TONELLO, Paulo Sergio. Uso das técnicas de difusão em filmes finos por gradiente de concentração (DGT) e ultrafiltração com fluxo tangencial no estudo da labilidade de Al(III) e Cu(II) em sistemas aquáticos. 2009. 123 f. Tese (doutorado) - Universidade Estadual Paulista, Instituto de Química, 2009. | - |
dc.identifier.uri | http://hdl.handle.net/11449/105690 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/105690 | - |
dc.description.abstract | As técnicas de ultrafiltração com fluxo tangencial (UF-FT) e de difusão em filmes finos por gradiente de concentração (DGT) foram empregadas no estudo da labilidade de Al e Cu em soluções modelo e em amostras de águas de dois rios do litoral do estado de São Paulo, rio Sorocabinha e rio Peropava. Como para técnica DGT, existe a necessidade de se conhecer o valor do coeficiente de difusão dos analitos em hidrogéis, foi construída uma câmara de difusão para a determinação desses coeficientes. As soluções modelo contendo diferentes concentrações de Al ou Cu, na presença de substâncias húmicas aquáticas (SHA), foram submetidas ao procedimento de UF-FT para a determinação das concentrações de metais livres e complexados. Com esses resultados e os coeficientes de difusão dos metais e seus complexos com substâncias húmicas, foram determinados coeficientes de difusão aparentes, específicos para cada solução modelo e/ou amostra. A técnica DGT convencional permitiu a determinação da fração lábil total dos analitos e, usando géis para difusão com diferentes porosidades, foi possível a determinação das frações inorgânicas e orgânicas dos analitos nas soluções modelo e/ou amostras. Para se verificar a exatidão dos resultados foi usado um procedimento de extração em fase sólida (EFS) com coluna preenchida com resina Chelex-100. Os resultados dos coeficientes de difusão de Al, Cu, Al-SH e Cu-SH, determinados através da câmara construída, foram similares aos encontrados na literatura para a mesma temperatura. Com os resultados da UF-FT, foram determinadas as capacidades complexantes das SH para Al e Cu em 3,7 e 1,0 mmol mg-1 de COT, para as SHA do rio Itapanhaú, e 3,9 e 7,4 mmol mg-1 de COT para as SHA do rio Sorocabinha. Os resultados da UF-FT e da DGT usando o coeficiente de difusão aparente não diferiram estatisticamente dos encontrados... | pt |
dc.description.abstract | The techniques of tangential flow ultrafiltration with (TF-UF) and diffusion gradients in thin films (DGT) were applied in the study of the lability of Al and Cu in model solutions and water samples from two rivers from the coast of the São Paulo state, the Sorocabinha and the Peropava River. As the DGT technique requires the values of the diffusion coefficients of the analytes in hydrogels, a diffusion chamber was built, in order to determine them. The model solutions, which contain different concentrations of Al and Cu when aquatic humic substances (AHS) are present, were submitted to the TF-UF procedure to determine the concentration of free and complexed metals. With these results and the diffusion coefficients of the metals and their complexes with humic substances, apparent diffusion coefficients, which are specific to every model solution and/or sample, were determined. The conventional DGT technique allowed the determination of the total labile fraction of the analytes and using diffusing gels with different pore size, the determination of the inorganic fractions of the analytes in the model solutions and/or samples was possible. To verify the accuracy of the results, a solid phase extraction procedure (SPE) was used, with the column filled with Chelex-100 resin. The results of the diffusion coefficients from Al(III), Cu(II), Al-HS and Cu-HS, determined through the built chamber, were similar to the ones found in the literature for the same temperature. With the TF-UF results the complexing capacities of the HS to Al and Cu were determined as 3.7 and 1.0 µmol mg-1 TOC to the AHS of the Itapanhaú River, and 3.9 and 7.4 µmol mg-1 TOC to the AHS of the Sorocabinha River. The TF-UF and DGT results using the apparent diffusion coefficients didn’t differ statistically to the ones found with the SPE, allowing thus the determination of the free, labile, labile more moderately labile... (Complete abstract click electronic access below) | en |
dc.format.extent | 123 f. : il. | - |
dc.language.iso | por | - |
dc.publisher | Universidade Estadual Paulista (UNESP) | - |
dc.source | Aleph | - |
dc.subject | Química ambiental | pt |
dc.subject | Quimica analitica | pt |
dc.subject | Especiação | pt |
dc.subject | Ultrafiltração | pt |
dc.subject | Analytical chemistry | en |
dc.title | Uso das técnicas de difusão em filmes finos por gradiente de concentração (DGT) e ultrafiltração com fluxo tangencial no estudo da labilidade de Al(III) e Cu(II) em sistemas aquáticos | pt |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | tonello_ps_dr_araiq_prot.pdf | - |
dc.identifier.aleph | 000594116 | - |
dc.identifier.capes | 33004030072P8 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.