You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/105722
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGomes Neto, José Anchieta [UNESP]-
dc.contributor.authorFranzini, Vanessa Pezza-
dc.date.accessioned2014-06-11T19:35:06Z-
dc.date.accessioned2016-10-25T19:37:27Z-
dc.date.available2014-06-11T19:35:06Z-
dc.date.available2016-10-25T19:37:27Z-
dc.date.issued2008-09-19-
dc.identifier.citationFRANZINI, Vanessa Pezza. Desenvolvimento de métodos analíticos para a determinação da concentração de fosfito em fertilizantes. 2009. 111 f. Tese (doutorado) - Universidade Estadual Paulista, Instituto de Química, 2009.-
dc.identifier.urihttp://hdl.handle.net/11449/105722-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/105722-
dc.description.abstractMétodos titrimétricos (convencional e biamperométrico) e amperométricos (manual e em fluxo) são propostos para determinar a concentração de fosfito em fertilizantes. Os métodos titrimétricos foram baseados na reação entre iodo e fosfito em meio de Na2HPO4/NaH2PO4 (pH = 6,8) a 70 °C. Alternativamente, pode ser feita a titulação convencional por retorno à temperatura ambiente, onde o excesso de iodo é titulado com tiossulfato. O consumo médio de reagentes corresponde a 200 mg KI, 127 mg I2, 174 mg Na2HPO4 e 176 mg NaH2PO4 por determinação. Os métodos amperométricos empregaram três eletrodos contendo: disco de 0,2 cm de raio de grafite quimicamente modificado com Pt e Pd (eletrodo de trabalho), um disco de platina de 0,2 cm2 (eletrodo auxiliar) e um eletrodo de Ag/AgCl,KClsat. (eletrodo de referência). No método manual, correlações lineares entre corrente de pico e concentração de fosfito foram obtidas no intervalo 0,01 - 0,04 mol L-1 H3PO3, apresentando sensibilidade de 30,54 mA L mol-1 H3PO3 com coeficiente de correlação linear R= 0,995. Na amperometria em fluxo, as correlações lineares entre corrente de pico e concentração de fosfito foram obtidas no intervalo 0,009 - 0,045 mol L-1 H3PO3, apresentando sensibilidade amperométrica de 2,42 mA L mol-1 H3PO3 com coeficiente de correlação linear R= 0,9997. Os resultados da análise de amostras comerciais, feitas em triplicata, para os quatro métodos foram concordantes com os resultados obtidos por espectrofotometria e com os valores nominais dos rótulos no nível de 95% de confiança.pt
dc.description.abstractClassical and biamperometric titrimetry, and manual and flow amperometric methods were proposed for phosphite determination in liquid fertilizer. The titrimetric methods were based on reaction of H3PO3 with standard iodine solution in Na2HPO4/ NaH2PO4 (pH = 6.8) media at 70°C. Alternatively, back titration is also feasible, where an excess of titrant at room temperature, is titrated with thiosulfate. The titration methods consumed about 200 mg KI, 127 mg I2, 174 mg Na2HPO4 and 176 mg by NaH2PO4 per determination. The manual and flow amperometric methods employed three electrodes containing: a disk of 0.2 cm in radius of graphite chemically modified with Pt and Pd (working electrode), a platinum disk of 0.2 cm2 (counter electrode) and an Ag / AgCl, KClsat. electrode (reference electrode). In the amperometric method, linearity between anodic current peak and phosphite concentration were obtained in the range 0.01- 0.04 mol L-1 H3PO3, the amperometric sensibility was 30.54 mA L mol-1 H3PO3 with good linear correlation coefficient (R=0.995). In flow-injection amperometry, linear correlation between anodic current peak and phosphite concentration were obtained in the range 0.009 – 0.045 mol L-1 H3PO3, the amperometric sensibility was 2.42 mA L mol-1 H3PO3 with good linear correlation coefficient (R=0.9997). The results of commercial samples analysed by four methods were in agreement with those obtained by spectrophotometry and the nominal values of the labels at 95% confidence level.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent111 f. : il.-
dc.language.isopor-
dc.publisherUniversidade Estadual Paulista (UNESP)-
dc.sourceAleph-
dc.subjectQuimica analiticapt
dc.subjectAnalise por injeção de fluxopt
dc.subjectAmperometriapt
dc.subjectAnalytical chemistryen
dc.titleDesenvolvimento de métodos analíticos para a determinação da concentração de fosfito em fertilizantespt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.rights.accessRightsAcesso aberto-
dc.identifier.filefranzini_vp_dr_araiq.pdf-
dc.identifier.aleph000589837-
dc.identifier.capes33004030072P8-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.