Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/109986
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Caritá, Renato Aparecido Corrêa | - |
dc.contributor.author | Caputo, Fabrizio | - |
dc.contributor.author | Greco, Camila Coelho | - |
dc.contributor.author | Denadai, Benedito Sérgio | - |
dc.date.accessioned | 2014-10-01T13:08:43Z | - |
dc.date.accessioned | 2016-10-25T19:45:32Z | - |
dc.date.available | 2014-10-01T13:08:43Z | - |
dc.date.available | 2016-10-25T19:45:32Z | - |
dc.date.issued | 2013-08-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S1517-86922013000400009 | - |
dc.identifier.citation | Revista Brasileira de Medicina do Esporte. Sociedade Brasileira de Medicina do Exercício e do Esporte, v. 19, n. 4, p. 271-274, 2013. | - |
dc.identifier.issn | 1517-8692 | - |
dc.identifier.uri | http://hdl.handle.net/11449/109986 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/109986 | - |
dc.description.abstract | INTRODUÇÃO: A determinação dos domínios de intensidade de exercício tem importantes implicações na prescrição do treino aeróbio e na elaboração de delineamentos experimentais. OBJETIVO: Analisar os efeitos do nível de aptidão aeróbia sobre a amplitude dos domínios de intensidade de exercício durante o ciclismo. MÉTODOS: Doze ciclistas (CIC), 11 corredores (COR) e oito indivíduos não treinados (NT) foram submetidos aos seguintes protocolos em diferentes dias: 1) teste progressivo para determinação do limiar de lactato (LL), consumo máximo de oxigênio (VO2máx) e sua respectiva intensidade (IVO2máx); 2) três testes de carga constante até a exaustão a 95, 100 e 110% IVO2máx para a determinação da potência crítica (PC); 3) testes até a exaustão para determinar a intensidade superior do domínio severo (Isup). As amplitudes dos domínios (moderado < LL; LL > pesado < PC; PC > severo < Isup) foram expressas como percentual da Isup (VO2). RESULTADOS: A amplitude do domínio moderado foi similar entre CIC (52 ± 8%) e COR (47 ± 4%) e significantemente maior no CIC em relação ao NT (41 ± 7%). O domínio pesado foi significantemente menor no CIC (17 ± 6%) em relação ao COR (27 ± 6%) e NT (27 ± 9%). Em relação ao domínio severo não foram encontradas diferenças significantes entre os CIC (31 ± 7%), COR (26 ± 5%) e NT (31 ± 7%). CONCLUSÃO: O domínio pesado de exercício é mais sensível a mudanças determinadas pelo nível de aptidão aeróbia, existindo a necessidade de que se atenda ao princípio da especificidade do movimento, quando se pretende obter um elevado grau de adaptação fisiológica. | pt |
dc.description.abstract | INTRODUCTION: The determination of the exercise intensity domains has important implications for the aerobic training prescription and elaboration of experimental designs. OBJECTIVE: The aim of this study was to analyze the effects of aerobic fitness level on the amplitude of the exercise intensity domains during cycling. METHODS: Twelve cyclists (CYC), eleven runners (RUN) and eight untrained subjects (NT) underwent the following protocols on different days: 1) progressive test to determine lactate threshold (LL), maximal oxygen uptake (VO2max) and its corresponding intensity (IVO(2max); 2) three constant workload tests until exhaustion at 95, 100 and 110% IVO2max to determine critical power (CP); 3) constant workload tests until exhaustion to determine the highest intensity at which VO2max is reached (Isup). RESULTS: The amplitude of the moderate domain was similar between CYC (52 ± 8%) and RUN (47 ± 4%) and significantly greater in CYC when compared with NT (41 ± 7%). The heavy domain was significantly smaller in CYC (17 ± 6%) when compared with RUN (27 ± 6%) and NT (27 ± 9%). In relation to severe domain, there were no significant differences among CYC (31 ± 7%), RUN (26 ± 5%) and NT (31 ± 7%). CONCLUSION: It can be concluded that the heavy domain is more sensitive to changes determined by the aerobic fitness level; there is a need hence to observe the training specificity, when high level of physiological adaptation is aimed. | en |
dc.format.extent | 271-274 | - |
dc.language.iso | por | - |
dc.publisher | Sociedade Brasileira de Medicina do Exercício e do Esporte | - |
dc.source | SciELO | - |
dc.subject | limiar anaeróbio | pt |
dc.subject | consumo de oxigênio | pt |
dc.subject | exercício aeróbio | pt |
dc.subject | anaerobic threshold | en |
dc.subject | oxygen consumption | en |
dc.subject | aerobic exercise | en |
dc.title | Aptidão aeróbia e amplitude dos domínios de intensidade de exercício no ciclismo | pt |
dc.title.alternative | Aerobic fitness and amplitude of the exercise intensity domains during cycling | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Universidade Estadual Paulista | - |
dc.description.affiliation | Universidade Estadual Paulista Universidade do Estado de Santa Catarina | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Universidade do Estado de Santa Catarina | - |
dc.identifier.doi | 10.1590/S1517-86922013000400009 | - |
dc.identifier.scielo | S1517-86922013000400009 | - |
dc.identifier.wos | WOS:000324916800009 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | S1517-86922013000400009.pdf | - |
dc.relation.ispartof | Revista Brasileira de Medicina do Esporte | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.