You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/11085
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSardenberg, Trajano-
dc.contributor.authorMüller, Sérgio Swain-
dc.contributor.authorMedeiros, Daniel Ricardo-
dc.contributor.authorBaptistão, Pablo Luiz-
dc.date.accessioned2014-05-20T13:32:30Z-
dc.date.available2014-05-20T13:32:30Z-
dc.date.issued2011-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0102-36162011000600006-
dc.identifier.citationRevista Brasileira de Ortopedia. Sociedade Brasileira de Ortopedia e Traumatologia, v. 46, n. 6, p. 656-659, 2011.-
dc.identifier.issn0102-3616-
dc.identifier.urihttp://hdl.handle.net/11449/11085-
dc.description.abstractOBJETIVO: Avaliar o método de Ulson de fixação intramedular associado à fixação externa variando a altura do travamento externo dos fios de Kirschner e sem fixação externa. MÉTODO: Foram utilizadas 18 tíbias de porcos, sendo realizada osteotomia transversal na região da tuberosidade e introduzidos dois fios de Kirschner intramedulares em cada peça, em três diferentes padrões de montagem: grupo I - travamento com minifixador externo com 3,0cm de altura; grupo II - travamento com 4,5cm de altura; grupo III: sem travamento externo. Realizaram-se ensaios mecânicos de cisalhamento, obtendo-se: carga máxima, limite de proporcionalidade e coeficiente de rigidez. RESULTADOS: Não foram encontradas diferenças significativas de carga máxima e limite de proporcionalidade entre os grupos; o grupo II apresentou maior coeficiente de rigidez. CONCLUSÃO: A altura do travamento dos fios de Kirschner no método de Ulson, dentro dos limites avaliados, não prejudicou a estabilidade do sistema de fixação da fratura.pt
dc.description.abstractOBJECTIVE: To evaluate the Ulson intramedullary fixation method, with external fixation in which the level of the external locking of the Kirschner wires is varied, and without external fixation. METHODS: Eighteen porcine tibias were used. Transverse osteotomy was performed in the region of the tuberosity, and two intramedullary Kirschner wires were inserted into each specimen, using three different assembly patterns: Group I: locking with external minifixator at a height of 3.0 cm; Group II: locking at a height of 4.5 cm; Group III: without external locking. Mechanical shear tests were then conducted, to determine the maximum load, proportionality limit and coefficient of rigidity. RESULTS: There were no significant differences in maximum load or proportionality limit between the groups. The coefficient of rigidity was higher in Group II. CONCLUSION: The locking height for the Kirschner wires in Ulson's method, within the limits evaluated, did not harm the stability of the fracture fixation system.en
dc.format.extent656-659-
dc.language.isopor-
dc.publisherSociedade Brasileira de Ortopedia e Traumatologia-
dc.sourceSciELO-
dc.subjectFraturas do Rádiopt
dc.subjectFixadores Externospt
dc.subjectBiomecânicapt
dc.subjectRadius Fracturesen
dc.subjectExternal Fixatorsen
dc.subjectBiomechanicsen
dc.titleEstudo mecânico da estabilidade dorsal da osteossíntese intramedular associada à fixação externa (método de Ulson)pt
dc.title.alternativeMechanical study on dorsal stability of intramedullary osteosynthesis associated with external fixation (Ulson's method)en
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP Faculdade de Medicina de Botucatu-
dc.description.affiliationUnespUNESP Faculdade de Medicina de Botucatu-
dc.identifier.doi10.1590/S0102-36162011000600006-
dc.identifier.scieloS0102-36162011000600006-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0102-36162011000600006.pdf-
dc.relation.ispartofRevista Brasileira de Ortopedia-