Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/11159
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Giannini, M. | - |
dc.contributor.author | Rollo, Hamilton Almeida | - |
dc.contributor.author | Maffei, Francisco Humberto de Abreu | - |
dc.contributor.author | Capvalho, L. R. | - |
dc.date.accessioned | 2014-05-20T13:32:41Z | - |
dc.date.accessioned | 2016-10-25T16:50:58Z | - |
dc.date.available | 2014-05-20T13:32:41Z | - |
dc.date.available | 2016-10-25T16:50:58Z | - |
dc.date.issued | 2008-12-01 | - |
dc.identifier | http://www.ncbi.nlm.nih.gov/pubmed/19078908 | - |
dc.identifier.citation | International Angiology. Turin: Edizioni Minerva Medica, v. 27, n. 6, p. 466-474, 2008. | - |
dc.identifier.issn | 0392-9590 | - |
dc.identifier.uri | http://hdl.handle.net/11449/11159 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/11159 | - |
dc.description.abstract | Aim. This study aimed at assessing the accuracy of ultrasound (US) in the diagnosis of recent deep vein thrombosis (DVT) in an experimental study in dogs.Methods. Design: blinded and randomized experimental study. Twenty dogs were randomly divided in two groups: control group (CG) and thrombosis group (TG). US was performed in the pre- and postoperative period. Phlebography was performed immediately prior to the postoperative US. After the second US, a surgery was performed to detect whether thrombus was present or not. US results were compared to those of phlebography and surgical findings.Results. in all dogs, inferior vena cava (IVC) was compressible. The relations of IVC diameter with the aorta were higher (P<0.005) in TG than in CG. Spectral Doppler in spontaneous breathing, tissue harmonic imaging, power Doppler and B flow showed sensitivity, specificity and accuracy of 1. Phlebography presented sensitivity of 90%, specificity of 80% and accuracy of 85%, when compared to surgical finding.Conclusion. For the diagnosis of recent DVT in the experimental model used, venous compressibility proved to be inefficient. The ratio of WC diameter to aorta, when increased, suggests thrombosis. The use of new US technological advances increases accuracy. Phlebography was less accurate than US. | en |
dc.format.extent | 466-474 | - |
dc.language.iso | eng | - |
dc.publisher | Edizioni Minerva Medica | - |
dc.source | Web of Science | - |
dc.subject | Ultrasonography | en |
dc.subject | Venous thrombosis, therapy | en |
dc.subject | Venous thrombosis, diagnosis | en |
dc.title | Advances in ultrasound techniques improve early detection of deep vein thrombosis | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Fac Med, Dept Orthoped Surg, Botucatu, SP, Brazil | - |
dc.description.affiliation | UNESP, Biosci Inst, Dept Biostat, Botucatu, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Fac Med, Dept Orthoped Surg, Botucatu, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Biosci Inst, Dept Biostat, Botucatu, SP, Brazil | - |
dc.identifier.wos | WOS:000263552200003 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | International Angiology | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.