You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/112117
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPinto, Andre Jinno G.-
dc.contributor.authorCosta, Eduardo Coelho M.-
dc.contributor.authorKurokawa, Sergio-
dc.contributor.authorMonteiro, Jose Humberto A.-
dc.contributor.authorFranco, Jorge Luiz de-
dc.contributor.authorPissolato, Jose-
dc.date.accessioned2014-12-03T13:09:14Z-
dc.date.accessioned2016-10-25T20:10:27Z-
dc.date.available2014-12-03T13:09:14Z-
dc.date.available2016-10-25T20:10:27Z-
dc.date.issued2014-05-01-
dc.identifierhttp://dx.doi.org/10.1016/j.ijepes.2013.12.015-
dc.identifier.citationInternational Journal Of Electrical Power & Energy Systems. Oxford: Elsevier Sci Ltd, v. 57, p. 358-365, 2014.-
dc.identifier.issn0142-0615-
dc.identifier.urihttp://hdl.handle.net/11449/112117-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/112117-
dc.description.abstractThe electrical characteristics of a new 280-m-tall transmission line are analyzed. The geometrical distance of the phases, wires height and physical structure of the line are intrinsic associated with its electrical performance in steady state as well as in transient conditions. Thus, a frequency-domain analysis is proposed comparing the longitudinal and transversal electrical parameters calculated from the tall transmission line with the same parameters obtained for a conventional 440-kV line. An adapted method for the mutual parameters is proposed to calculate the shunt capacitances considering two dielectrics between the wires and ground (air and forest), taking into account that the new transmission system has not a corridor, as usually observed in conventional lines. A second analysis is performed based on both lines modeling and time-domain simulations using the EMTP. Electromagnetic transient simulations from an atmospheric impulse shows that the tall transmission line has a major transient overvoltage than a conventional line. In sequence, an alternative surge protection is proposed using metal-oxide arresters connected directly at the phases, in parallel with the line insulators. The main objective of this technical report is to evaluate the electrical characteristics of the new transmission system using tall structures and, by this means, to highlight the possible variations concerning its operation and transient response. (C) 2013 Elsevier Ltd. All rights reserved.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent358-365-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectTall transmission towersen
dc.subjectFrequency-domain analysisen
dc.subjectElectromagnetic transientsen
dc.subjectLightning performanceen
dc.subjectSurge arrestersen
dc.titleAnalysis of the electrical characteristics and surge protection of EHV transmission lines supported by tall towersen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Campinas Unicamp, High Voltage Lab, Campinas, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista Unesp, Fac Engn Ilha Solteira Feis, Ilha Solteira, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Unesp, Fac Engn Ilha Solteira Feis, Ilha Solteira, SP, Brazil-
dc.description.sponsorshipIdCAPES: 4570-11-1-
dc.description.sponsorshipIdFAPESP: 13/00974-5-
dc.identifier.doi10.1016/j.ijepes.2013.12.015-
dc.identifier.wosWOS:000331772700038-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Electrical Power & Energy Systems-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.