You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/112964
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBergoli, Cesar Dalmolin-
dc.contributor.authorCosta Lima, Julia Magalhaes da-
dc.contributor.authorMelo, Renata Marques de-
dc.contributor.authorBottino, Marco Antonio-
dc.contributor.authorValandro, Luiz Felipe-
dc.date.accessioned2014-12-03T13:11:11Z-
dc.date.accessioned2016-10-25T20:12:24Z-
dc.date.available2014-12-03T13:11:11Z-
dc.date.available2016-10-25T20:12:24Z-
dc.date.issued2014-04-01-
dc.identifierhttp://dx.doi.org/10.1016/j.ijadhadh.2013.12.024-
dc.identifier.citationInternational Journal Of Adhesion And Adhesives. Oxford: Elsevier Sci Ltd, v. 50, p. 7-10, 2014.-
dc.identifier.issn0143-7496-
dc.identifier.urihttp://hdl.handle.net/11449/112964-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/112964-
dc.description.abstractPurpose: To verify the influence of different instruments and operators on the bonding interfacial area and on the push-out bond strength values.Material and methods: Fifteen anterior human teeth (n=15) were selected, cleaned and standardized to 15 mm length. Root canals were prepared in 12 mm and the fiber posts were cemented using the RelyX U-100 cement. Three slices were obtained per tooth (N=45) and submitted to the push-out bond strength test. The bonding interfacial area (mm(2)) of each specimen was calculated based on the disc slice dimensions: coronal and apical diameter and height. The bonding area of each specimen was used to calculate the bond strength (Mpa). The dimensions were analyzed by different operators, using two instruments: G1 - Operator A with a digital caliper; G2 - Operator A with a stereomicroscope; G3 - Operator B with a digital caliper; G4 - Operator B with a digital stereomicroscope; G5 - Operator C with a digital caliper; G6 - Operator C with a stereomicroscope. The mean area was submitted to inter-operator and intra-operator analyses, while the mean area and mean of bond strength were submitted to the 2-way ANOVA with repeated measures and the Tukey test (alpha=0.05).Results: The inter-operator kappa was 0.83 to the digital caliper and 0.91 to the stereomicroscope, while the intra-operator kappa was 0.76. The operator and the measurement instrument influenced the interfacial bonding area (p=0.000 and p=0.001) and the push-out bond strength values (p=0.000 and p=0.000, respectively) of the disc slices.Conclusion: The final push-out bond strength values are influenced by the measuring instrument and by the measurer operator. (C) 2014 Published by Elsevier Ltd.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent7-10-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectFiber posten
dc.subjectCompositeen
dc.subjectMicroscopyen
dc.subjectBond strengthen
dc.titleEffect of the interfacial area measurement parameters on the push-out strength between fiber post and dentinen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Sergipe (UFS)-
dc.description.affiliationSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, BR-12245000 Sao Paulo, Brazil-
dc.description.affiliationSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, Dept Dent Mat & Prosthodont, BR-12245000 Sao Paulo, Brazil-
dc.description.affiliationUniv Fed Santa Maria, Fac Odontol, Prosthodont Unit, BR-97015372 Santa Maria, RS, Brazil-
dc.description.affiliationUnespSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, BR-12245000 Sao Paulo, Brazil-
dc.description.affiliationUnespSao Paulo State Univ UNESP, Sao Jose Campos Dent Sch, Dept Dent Mat & Prosthodont, BR-12245000 Sao Paulo, Brazil-
dc.description.sponsorshipIdFAPESP: 11/09897-8-
dc.identifier.doi10.1016/j.ijadhadh.2013.12.024-
dc.identifier.wosWOS:000334139700002-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Adhesion and Adhesives-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.