You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/112971
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOliveira de Vasconcellos, Luis Gustavo-
dc.contributor.authorNishioka, Renato Sussumu-
dc.contributor.authorReis de Vasconcellos, Luana Marotta-
dc.contributor.authorBalducci, Ivan-
dc.contributor.authorKojima, Alberto Noriyuki-
dc.date.accessioned2014-12-03T13:11:12Z-
dc.date.accessioned2016-10-25T20:12:25Z-
dc.date.available2014-12-03T13:11:12Z-
dc.date.available2016-10-25T20:12:25Z-
dc.date.issued2013-11-01-
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e31829ac83d-
dc.identifier.citationJournal Of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 24, n. 6, p. E546-E551, 2013.-
dc.identifier.issn1049-2275-
dc.identifier.urihttp://hdl.handle.net/11449/112971-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/112971-
dc.description.abstractThe current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.en
dc.format.extentE546-E551-
dc.language.isoeng-
dc.publisherLippincott Williams & Wilkins-
dc.sourceWeb of Science-
dc.subjectStrain gauge analysisen
dc.subjectdental implantsen
dc.subjectdental prosthesisen
dc.subjectimplant-supported dental prosthesisen
dc.titleMicrostrain Around Dental Implants Supporting Fixed Partial Prostheses Under Axial and Non-Axial Loading Conditions, In Vitro Strain Gauge Analysisen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSao Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil-
dc.description.affiliationSao Paulo State Univ UNESP, Dept Biosci & Buccal Diag, Sao Jose Dos Campos, Brazil-
dc.description.affiliationSao Paulo State Univ UNESP, Dept Social Dent, Sao Jose Dos Campos, Brazil-
dc.description.affiliationSao Paulo State Univ UNESP, Childrens Clin, Sch Dent Sao Jose dos Campos, Sao Jose Dos Campos, Brazil-
dc.description.affiliationUnespSao Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Sao Jose Dos Campos, Brazil-
dc.description.affiliationUnespSao Paulo State Univ UNESP, Dept Biosci & Buccal Diag, Sao Jose Dos Campos, Brazil-
dc.description.affiliationUnespSao Paulo State Univ UNESP, Dept Social Dent, Sao Jose Dos Campos, Brazil-
dc.description.affiliationUnespSao Paulo State Univ UNESP, Childrens Clin, Sch Dent Sao Jose dos Campos, Sao Jose Dos Campos, Brazil-
dc.identifier.doi10.1097/SCS.0b013e31829ac83d-
dc.identifier.wosWOS:000330354500005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Craniofacial Surgery-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.