dc.contributor.authorKogawa, Ana Carolina-
dc.contributor.authorSalgado, Hérida Regina Nunes-
dc.date.accessioned2014-12-03T13:11:43Z-
dc.date.accessioned2016-10-25T20:14:57Z-
dc.date.available2014-12-03T13:11:43Z-
dc.date.available2016-10-25T20:14:57Z-
dc.date.issued2013-11-01-
dc.identifierhttp://dx.doi.org/10.1093/chromsci/bms190-
dc.identifier.citationJournal Of Chromatographic Science. Cary: Oxford Univ Press Inc, v. 51, n. 10, p. 919-925, 2013.-
dc.identifier.issn0021-9665-
dc.identifier.urihttp://hdl.handle.net/11449/113470-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/113470-
dc.description.abstractAn accurate, sensitive, precise and rapid gradient reversed-phase high-performance liquid chromatographic method was successfully developed and validated for the determination of doxycycline hyclate in bulk drug and tablets. The best separation was achieved on a 250 x 4.6 mm, 5.0 mu m particle size CN Luna column with water + 0.1% TFA-acetonitrile + 0.1% TFA, 60:40 (v/v) as the mobile phase at a flow rate of 1.0 mL/min. Ultraviolet detection was performed at 360 nm at ambient column temperature (25 degrees C). The method was linear over the concentration range of 50-100 mg/mL (r = 50.9999) with limits of detection and quantification of 2.83 and 8.59 mu g/mL, respectively. The drug was subjected to oxidation, acid, base and neutral degradation, photolysis and heat as stress conditions. Degradation products were found interfering with the assay of doxycycline hyclate, therefore the method can be regarded as suitable. The method was applied for the determination of doxycycline hyclate in standard and pharmaceutical products, with excellent recoveries. The method can be used for the quality control of doxycycline hyclate.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.description.sponsorshipPADC/FCF/UNESP (Programa de Apoio ao Desenvolvimento Cientifico/Faculdade de Ciencias Farmaceuticas/Universidade Estadual Paulista, Araraquara, Brazil)-
dc.description.sponsorshipUniao Quimica Industria Farmaceutica-
dc.format.extent919-925-
dc.language.isoeng-
dc.publisherOxford University Press-
dc.sourceWeb of Science-
dc.titleQuantification of Doxycycline Hyclate in Tablets by HPLC-UV Methoden
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista Julio de Mesquita Filho UN, Fac Pharmaceut Sci Araraquara, Dept Drugs & Med, Sao Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Julio de Mesquita Filho UN, Fac Pharmaceut Sci Araraquara, Dept Drugs & Med, Sao Paulo, Brazil-
dc.identifier.doi10.1093/chromsci/bms190-
dc.identifier.wosWOS:000328324300005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Chromatographic Science-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.