Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/113483
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moraes, Natália Valadares de | - |
dc.contributor.author | Lauretti, Gabriela Rocha | - |
dc.contributor.author | Oliveira Filgueira, Gabriela Campos de | - |
dc.contributor.author | Portes Lopes, Bruno Carvalho | - |
dc.contributor.author | Lanchote, Vera Lucia | - |
dc.date.accessioned | 2014-12-03T13:11:44Z | - |
dc.date.accessioned | 2016-10-25T20:14:59Z | - |
dc.date.available | 2014-12-03T13:11:44Z | - |
dc.date.available | 2016-10-25T20:14:59Z | - |
dc.date.issued | 2014-03-05 | - |
dc.identifier | http://dx.doi.org/10.1016/j.jpba.2013.11.032 | - |
dc.identifier.citation | Journal Of Pharmaceutical And Biomedical Analysis. Amsterdam: Elsevier Science Bv, v. 90, p. 180-185, 2014. | - |
dc.identifier.issn | 0731-7085 | - |
dc.identifier.uri | http://hdl.handle.net/11449/113483 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/113483 | - |
dc.description.abstract | Rocuronium (ROC) is a neuromuscular blocking agent used in surgical procedures which is eliminated primarily by biliary excretion. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of ROC in human plasma. Separation of ROC and IS (verapamil) was performed using an endcapped C-18 column and a mixture of water:acetonitrile:trifluoracetic acid (50:50:0.1, v/v) as mobile phase. Aliquots of 100 mu L of human plasma were extracted at pH 3, using dichloromethane. The lower limit of quantification of 5 ng/mL shows the high sensitivity of this method. Intra- and inter-assay precision (as relative standard deviation) was all <= 14.2% and accuracy (as relative standard error) did not exceed 10.1%. The validated method was successfully applied to quantify ROC concentrations in patients under surgical procedures up to 6 h after the administration of the 0.4-0.9 mg/kg ROC. The pharmacokinetic parameter estimations of ROC showed AUC/dose of 563 mu g min/mL, total clearance of 2.5 mL/min/kg, volume of distribution at steady state of 190 mL/kg and mean residence time of 83 min. (C) 2013 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 180-185 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | Rocuronium | en |
dc.subject | LC-MS/MS | en |
dc.subject | Human plasma | en |
dc.subject | Pharmacokinetics | en |
dc.title | Analysis of rocuronium in human plasma by liquid chromatography-tandem mass spectrometry with application in clinical pharmacokinetics | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Univ Estadual Paulista, Fac Ciencias Farmaceut, Dept Principios Ativos Nat & Toxicol, BR-14801902 Araraquara, SP, Brazil | - |
dc.description.affiliation | Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Biomecan Med & Reabilitado Sistema Locomotor, BR-14049900 Ribeirao Preto, SP, Brazil | - |
dc.description.affiliation | Univ Sao Paulo, Fac Med Ribeirao Preto, Dept Obstet & Ginecol, BR-14049900 Ribeirao Preto, SP, Brazil | - |
dc.description.affiliation | Univ Sao Paulo, Fac Ciencias Farmaceut Ribeirao Preto, Dept Analises Clin Toxicol & Bromatol, BR-14040903 Ribeirao Preto, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Ciencias Farmaceut, Dept Principios Ativos Nat & Toxicol, BR-14801902 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.jpba.2013.11.032 | - |
dc.identifier.wos | WOS:000331854600023 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Pharmaceutical and Biomedical Analysis | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.