You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/11548
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDanaga, Aline Roberta-
dc.contributor.authorGut, Ana Lúcia-
dc.contributor.authorAntunes, Letícia Cláudia de Oliveira-
dc.contributor.authorFerreira, Ana Lúcia dos Anjos-
dc.contributor.authorYamaguti, Fábio Akio-
dc.contributor.authorChristovan, José Carlos-
dc.contributor.authorTeixeira, Ubirajara-
dc.contributor.authorGuedes, Cristina Aparecida Veloso-
dc.contributor.authorSasseron, Ana Beatriz-
dc.contributor.authorMartin, Luis Cuadrado-
dc.date.accessioned2014-05-20T13:33:43Z-
dc.date.available2014-05-20T13:33:43Z-
dc.date.issued2009-06-01-
dc.identifierhttp://dx.doi.org/10.1590/S1806-37132009000600007-
dc.identifier.citationJornal Brasileiro de Pneumologia. Sociedade Brasileira de Pneumologia e Tisiologia, v. 35, n. 6, p. 541-547, 2009.-
dc.identifier.issn1806-3713-
dc.identifier.urihttp://hdl.handle.net/11449/11548-
dc.description.abstractOBJETIVO: Avaliar o desempenho diagnóstico do índice de respiração rápida e superficial (IRRS) na predição do insucesso da extubação de pacientes adultos em terapia intensiva e verificar a adequação do valor de corte clássico para esse índice. MÉTODOS: Estudo prospectivo realizado na unidade de terapia intensiva de adultos do Hospital das Clínicas da Faculdade de Medicina de Botucatu, através da avaliação do IRRS em 73 pacientes consecutivos considerados clinicamente prontos para extubação. RESULTADOS: O IRRS com valor de corte clássico (105 ciclos/min/L) apresentou sensibilidade de 20% e especificidade de 95% (soma = 115%). A análise da curva receiver operator characteristic (ROC) demonstrou melhor valor de corte (76,5 ciclos/min/L), o qual forneceu sensibilidade de 66% e especificidade de 74% (soma = 140%), e a área sob a curva ROC para o IRRS foi de 0,78. CONCLUSÕES: O valor de corte clássico do IRRS se mostrou inadequado nesta casuística, prevendo apenas 20% dos pacientes com falha na extubação. A obtenção do novo valor de corte permitiu um acréscimo substancial de sensibilidade, com aceitável redução da especificidade. O valor da área sob a curva ROC indicou satisfatório poder discriminativo do índice, justificando a validação de sua aplicação.pt
dc.description.abstractOBJECTIVE: To evaluate the diagnostic performance of the rapid shallow breathing index (RSBI) in predicting extubation failure among adult patients in the intensive care unit and to determine the appropriateness of the classical RSBI cut-off value. METHODS: This was a prospective study conducted in the adult intensive care unit of the Botucatu School of Medicine Hospital das Clínicas. The RSBI was evaluated in 73 consecutive patients considered clinically ready for extubation. RESULTS: The classical RSBI cut-off value (105 breaths/min/L) presented a sensitivity of 20% and a specificity of 95% (sum = 115%). Analysis of the receiver operator characteristic (ROC) curve revealed a better cut-off value (76.5 breaths/min/L), which presented a sensitivity of 66% and a specificity of 74% (sum = 140%). The area under the ROC curve for the RSBI was 0.78. CONCLUSIONS: The classical RSBI cut-off value proved inappropriate, predicting only 20% of the cases of extubation failure in our sample. The new cut-off value provided substantial improvement in sensitivity, with an acceptable loss of specificity. The area under the ROC curve indicated that the discriminative power of the RSBI is satisfactory, which justifies the validation of this index for use.en
dc.format.extent541-547-
dc.language.isopor-
dc.publisherSociedade Brasileira de Pneumologia e Tisiologia-
dc.sourceSciELO-
dc.subjectAdultopt
dc.subjectCuidados intensivospt
dc.subjectCurva ROCpt
dc.subjectDesmame do respiradorpt
dc.subjectDiagnósticopt
dc.subjectRespiração artificialpt
dc.subjectAdulten
dc.subjectIntensive careen
dc.subjectROC curveen
dc.subjectVentilator weaningen
dc.subjectDiagnosisen
dc.subjectRespiration, artificialen
dc.titleAvaliação do desempenho diagnóstico e do valor de corte para o índice de respiração rápida e superficial na predição do insucesso da extubaçãopt
dc.title.alternativeEvaluation of the diagnostic performance and cut-off value for the rapid shallow breathing index in predicting extubation failureen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionCentro Universitário Hermínio Ometto - UNIARARAS-
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Medicina de Botucatu-
dc.description.affiliationCentro Universitário Hermínio Ometto - UNIARARAS-
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Medicina de Botucatu Departamento de Clínica Médica-
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Medicina de Botucatu-
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Medicina de Botucatu Departamento de Clínica Médica-
dc.identifier.doi10.1590/S1806-37132009000600007-
dc.identifier.scieloS1806-37132009000600007-
dc.identifier.wosWOS:000269020100007-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS1806-37132009000600007.pdf-
dc.relation.ispartofJornal Brasileiro de Pneumologia-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.