You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/116191
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCincotto, Fernando H.-
dc.contributor.authorCanevari, Thiago C.-
dc.contributor.authorMachado, Sergio A. S.-
dc.date.accessioned2015-03-18T15:52:33Z-
dc.date.accessioned2016-10-25T20:23:34Z-
dc.date.available2015-03-18T15:52:33Z-
dc.date.available2016-10-25T20:23:34Z-
dc.date.issued2014-12-01-
dc.identifierhttp://dx.doi.org/10.1002/elan.201400451-
dc.identifier.citationElectroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 26, n. 12, p. 2783-2788, 2014.-
dc.identifier.issn1040-0397-
dc.identifier.urihttp://hdl.handle.net/11449/116191-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/116191-
dc.description.abstractThis paper describes the electrochemical determination of vitamin D-2 (ergocalciferol) and D-3 (cholecalciferol) in mixed organic/water solvent, using a glassy carbon electrode (GCE). The mixing ratio of organic/water solvent has an important influence on the electrocatalytic response of D vitamins on the surface of the glassy carbon electrode. Well-defined peaks for Vitamin D-2 and D-3 were observed in a 40% ethanol/60% water solution with lithium perchlorate as the support electrolyte. This study demonstrated that the glassy carbon electrode is highly sensitive for the determination of vitamin D-2 and D-3, with a limit of detection of 0.13 and 0.118 mu molL(-1), respectively. No significant interference was seen for vitamins A, E and K in the detection of vitamin D.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent2783-2788-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectVitamin Den
dc.subjectElectrochemical sensorsen
dc.subjectOrganic/water solutionen
dc.subjectElectroanalysisen
dc.titleHighly Sensitive Electrochemical Sensor for Determination of Vitamin D in Mixtures of Water-Ethanolen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationState Univ Sao Paulo, Inst Chem, BR-13560970 Sao Carlos, SP, Brazil-
dc.description.affiliationUnespState Univ Sao Paulo, Inst Chem, BR-13560970 Sao Carlos, SP, Brazil-
dc.description.sponsorshipIdFAPESP: 11/23047-7-
dc.description.sponsorshipIdFAPESP: 12/18339-1-
dc.identifier.doi10.1002/elan.201400451-
dc.identifier.wosWOS:000345978300029-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofElectroanalysis-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.