Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/116259
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pellizzer, Eduardo Piza | - |
dc.contributor.author | Santiago Junior, Joel Ferreira | - |
dc.contributor.author | Ribeiro Villa, Luiz Marcelo | - |
dc.contributor.author | Souza Batista, Victor Eduardo de | - |
dc.contributor.author | Mello, Caroline Cantieri de | - |
dc.contributor.author | Faria Almeida, Daniel Augusto de | - |
dc.contributor.author | Honrio, Heitor Marques | - |
dc.date.accessioned | 2015-03-18T15:52:58Z | - |
dc.date.accessioned | 2016-10-25T20:24:22Z | - |
dc.date.available | 2015-03-18T15:52:58Z | - |
dc.date.available | 2016-10-25T20:24:22Z | - |
dc.date.issued | 2014-10-01 | - |
dc.identifier | http://dx.doi.org/10.1007/s00340-014-5827-9 | - |
dc.identifier.citation | Applied Physics B-lasers And Optics. New York: Springer, v. 117, n. 1, p. 235-244, 2014. | - |
dc.identifier.issn | 0946-2171 | - |
dc.identifier.uri | http://hdl.handle.net/11449/116259 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/116259 | - |
dc.description.abstract | The aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis. | en |
dc.format.extent | 235-244 | - |
dc.language.iso | eng | - |
dc.publisher | Springer | - |
dc.source | Web of Science | - |
dc.title | Photoelastic stress analysis of splinted and unitary implant-supported prostheses | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Univ Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16016050 Sao Paulo, Brazil | - |
dc.description.affiliation | Univ Sao Paulo, Bauru Sch Dent, Discipline Res Methodol & Stat, Dept Pediat Dent Orthodont & Publ Hlth, BR-17012901 Sao Paulo, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16016050 Sao Paulo, Brazil | - |
dc.identifier.doi | 10.1007/s00340-014-5827-9 | - |
dc.identifier.wos | WOS:000342225300028 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Applied Physics B-lasers And Optics | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.