You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/116259
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPellizzer, Eduardo Piza-
dc.contributor.authorSantiago Junior, Joel Ferreira-
dc.contributor.authorRibeiro Villa, Luiz Marcelo-
dc.contributor.authorSouza Batista, Victor Eduardo de-
dc.contributor.authorMello, Caroline Cantieri de-
dc.contributor.authorFaria Almeida, Daniel Augusto de-
dc.contributor.authorHonrio, Heitor Marques-
dc.date.accessioned2015-03-18T15:52:58Z-
dc.date.accessioned2016-10-25T20:24:22Z-
dc.date.available2015-03-18T15:52:58Z-
dc.date.available2016-10-25T20:24:22Z-
dc.date.issued2014-10-01-
dc.identifierhttp://dx.doi.org/10.1007/s00340-014-5827-9-
dc.identifier.citationApplied Physics B-lasers And Optics. New York: Springer, v. 117, n. 1, p. 235-244, 2014.-
dc.identifier.issn0946-2171-
dc.identifier.urihttp://hdl.handle.net/11449/116259-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/116259-
dc.description.abstractThe aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis.en
dc.format.extent235-244-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.titlePhotoelastic stress analysis of splinted and unitary implant-supported prosthesesen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUniv Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16016050 Sao Paulo, Brazil-
dc.description.affiliationUniv Sao Paulo, Bauru Sch Dent, Discipline Res Methodol & Stat, Dept Pediat Dent Orthodont & Publ Hlth, BR-17012901 Sao Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16016050 Sao Paulo, Brazil-
dc.identifier.doi10.1007/s00340-014-5827-9-
dc.identifier.wosWOS:000342225300028-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofApplied Physics B-lasers And Optics-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.