Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/116943
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Perlatti D'Alpino, Paulo Henrique | - |
dc.contributor.author | Silva, Marilia Santos | - |
dc.contributor.author | Miranda Gonzalez, Alejandra Hortencia | - |
dc.contributor.author | Rodrigues, Flavia Pires | - |
dc.date.accessioned | 2015-03-18T15:54:33Z | - |
dc.date.accessioned | 2016-10-25T20:28:27Z | - |
dc.date.available | 2015-03-18T15:54:33Z | - |
dc.date.available | 2016-10-25T20:28:27Z | - |
dc.date.issued | 2014-09-01 | - |
dc.identifier | http://dx.doi.org/10.1080/01694243.2014.914013 | - |
dc.identifier.citation | Journal Of Adhesion Science And Technology. Abingdon: Taylor & Francis Ltd, v. 28, n. 17, p. 1711-1724, 2014. | - |
dc.identifier.issn | 0169-4243 | - |
dc.identifier.uri | http://hdl.handle.net/11449/116943 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/116943 | - |
dc.description.abstract | Purpose: To evaluate the influence of filling techniques and consistency of low-shrinkage composites on the bond strength and internal gap formation in Class I bonded restorations. Two low-shrinkage restorative systems (N'Durance/Septodont and Filtek Silorane/3M ESPE) were used to restore Class I preparations. Bulk increment, two oblique increments or two horizontal increments were performed and Filtek Z350XT was used as a control. Each increment was photoactivated for 40 s and the restored teeth were then stored for 24 h at 37 degrees C before being longitudinally sectioned and the internal margins of the restorations dyed with 1% acid-red propylene glycol solution for 20 s. The specimens were water rinsed and digital images were recorded for the internal gap formation (%) analysis. Stick-shaped specimens were also tested in tension to evaluate the bond strength. Comparative consistency of unset composites was also performed. N'Durance exhibited the highest incidence of internal gaps amongst all the filling techniques. Filtek Silorane showed no significant difference of internal gap formation in comparison with Filtek Z350XT, regardless of the filling technique. Filtek Z350XT exhibited the highest bond strength and N'Durance the lowest when horizontally applied; bond strength of Filtek Silorane was not influenced by the filling technique. Both Filtek Z350XT and N'Durance presented lower consistency. Low-shrinkage composites seem to present equivalent or inferior bond strength and internal gap formation when compared to the methacrylate composite. The quality of the Class I preparation is dependent on the material and filling techniques. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | - |
dc.format.extent | 1711-1724 | - |
dc.language.iso | eng | - |
dc.publisher | Taylor & Francis Ltd | - |
dc.source | Web of Science | - |
dc.subject | low-shrinkage composites | en |
dc.subject | bond strength | en |
dc.subject | consistency | en |
dc.title | Interfacial integrity of low-shrinkage composite restorations related to the filling technique and consistency | en |
dc.type | outro | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.contributor.institution | Univ Birmingham | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Anhanguera Univ Sao Paulo UNIAN SP, Sch Dent, Biomat Res Grp, BR-02071013 Sao Paulo, Brazil | - |
dc.description.affiliation | Univ Birmingham, Sch Dent, Biomat Unit, Coll Med & Dent Sci, Birmingham B4 6NN, W Midlands, England | - |
dc.description.affiliation | UNESP Univ Estadual Paulista, Dept Dent Mat & Prosthodont, Sch Dent, Inst Sci & Technol, BR-12245000 Sao Jose Dos Campos, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP Univ Estadual Paulista, Dept Dent Mat & Prosthodont, Sch Dent, Inst Sci & Technol, BR-12245000 Sao Jose Dos Campos, SP, Brazil | - |
dc.description.sponsorshipId | FAPESP: 10/16289-1-PI | - |
dc.description.sponsorshipId | FAPESP: 05/58446-8-PI | - |
dc.description.sponsorshipId | CNPq: 479744/2010-6 | - |
dc.description.sponsorshipId | CNPq: 163102/2011-2-PI | - |
dc.identifier.doi | 10.1080/01694243.2014.914013 | - |
dc.identifier.wos | WOS:000338013100005 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal Of Adhesion Science And Technology | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.