You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/117016
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCorazza, Pedro Henrique-
dc.contributor.authorSilva, Alecsandro de Moura-
dc.contributor.authorCavalcanti Queiroz, Jose Renato-
dc.contributor.authorSalazar Marocho, Susana Maria-
dc.contributor.authorBottino, Marco Antonia-
dc.contributor.authorMassi, Marcos-
dc.contributor.authorAssuncao e Souza, Rodrigo Othavio de-
dc.date.accessioned2015-03-18T15:54:44Z-
dc.date.accessioned2016-10-25T20:32:02Z-
dc.date.available2015-03-18T15:54:44Z-
dc.date.available2016-10-25T20:32:02Z-
dc.date.issued2014-08-01-
dc.identifierhttp://dx.doi.org/10.1097/ID.0000000000000111-
dc.identifier.citationImplant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 23, n. 4, p. 434-438, 2014.-
dc.identifier.issn1056-6163-
dc.identifier.urihttp://hdl.handle.net/11449/117016-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/117016-
dc.description.abstractPurpose: To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC).Materials and Methods: Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw. RT values were measured and registered. Data (in Newton centimeter) were analyzed with analysis of variance and Dunnet test (alpha = 0.05).Results: RT values were significantly affected by MC (P = 0.001) and the interaction between DLC coating and MC (P = 0.038). SCy and ACy showed the lowest RT values, statistically different from the control. The abutment coated groups had no statistical difference compared with the control. Scanning electron microscopy analysis showed DLC film with a thickness of 3 mm uniformly coating the hexagonal abutment.Conclusion: DLC film deposited on the abutment can be used as an alternative procedure to reduce abutment screw loosening.en
dc.description.sponsorshipLAS/INPE (Sao Jose dos Campos, Brazil)-
dc.format.extent434-438-
dc.language.isoeng-
dc.publisherLippincott Williams & Wilkins-
dc.sourceWeb of Science-
dc.subjectabutmenten
dc.subjectDLCen
dc.subjectimplanten
dc.subjectplasmaen
dc.titleCarbon Film Coating of Abutment Surfaces: Effect on the Abutment Screw Removal Torqueen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionTechnol Inst Aeronaut-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionFed Univ Rio Grande do Norte UFRN-
dc.description.affiliationSao Paulo State Univ, Dept Dent Mat & Prosthodont, Inst Sci & Technol Sao Jose dos Campos, Sao Jose Dos Campos, Brazil-
dc.description.affiliationTechnol Inst Aeronaut, Dept Phys, Sao Jose Dos Campos, Brazil-
dc.description.affiliationUniv Sao Paulo, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil-
dc.description.affiliationFed Univ Rio Grande do Norte UFRN, Dept Dent, Div Prosthodont, BR-59056000 Natal, RN, Brazil-
dc.description.affiliationUnespSao Paulo State Univ, Dept Dent Mat & Prosthodont, Inst Sci & Technol Sao Jose dos Campos, Sao Jose Dos Campos, Brazil-
dc.identifier.doi10.1097/ID.0000000000000111-
dc.identifier.wosWOS:000340373100012-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofImplant Dentistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.