You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/117185
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPesqueira, Aldieris Alves-
dc.contributor.authorGoiato, Marcelo Coelho-
dc.contributor.authorFreitas da Silva, Emily Vivianne-
dc.contributor.authorHaddad, Marcela Filie-
dc.contributor.authorMoreno, Amalia-
dc.contributor.authorZahoui, Abbas-
dc.contributor.authorSantos, Daniela Micheline dos-
dc.date.accessioned2015-03-18T15:55:23Z-
dc.date.accessioned2016-10-25T20:34:27Z-
dc.date.available2015-03-18T15:55:23Z-
dc.date.available2016-10-25T20:34:27Z-
dc.date.issued2014-06-01-
dc.identifierhttp://dx.doi.org/10.1117/1.JBO.19.6.066012-
dc.identifier.citationJournal Of Biomedical Optics. Bellingham: Spie-soc Photo-optical Instrumentation Engineers, v. 19, n. 6, 5 p., 2014.-
dc.identifier.issn1083-3668-
dc.identifier.urihttp://hdl.handle.net/11449/117185-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/117185-
dc.description.abstractIn part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-retained palatal obturator prostheses associated with different attachment systems: BOC-splinted implants with a bar connected to two centrally placed O-rings, and BOD-splinted implants with a BC connected to two distally placed O-rings (cantilever). One photoelastic model of the maxilla with oral-sinus-nasal communication with three parallel implants was fabricated. Afterward, two implant-retained palatal obturator prostheses with the two attachment systems described above were constructed. Each assembly was positioned in a circular polariscope and a 100-N axial load was applied in three different regions with implants by using a universal testing machine. The results were obtained through photograph record analysis of stress. The BOD system exhibited the highest stress concentration, followed by the BOC system. The O-ring, centrally placed on the bar, allows higher mobility of the prostheses and homogeneously distributes the stress to the region of the alveolar ridge and implants. It can be concluded that the use of implants with O-rings, isolated or connected with a bar, to rehabilitate maxillectomized patients allows higher prosthesis mobility and homogeneously distributes the stress to the alveolar ridge region, which may result in greater chewing stress distribution to implants and bone tissue. The clinical implication of the augmented bone support loss after maxillectomy is the increase of stress in the attachment systems and, consequently, a higher tendency for displacement of the prosthesis. (C) 2014 Society of Photo-Optical Instrumentation Engineers (SPIE).en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent5-
dc.language.isoeng-
dc.publisherSpie-soc Photo-optical Instrumentation Engineers-
dc.sourceWeb of Science-
dc.subjectphotoelastic imagingen
dc.subjectdental implanten
dc.subjectpalatal obturatorsen
dc.subjectmaxillofacial prosthesisen
dc.titleStress analysis in oral obturator prostheses, part II: photoelastic imagingen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionFed Univ Alfenas Unifal-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP, Brazil-
dc.description.affiliationFed Univ Alfenas Unifal, Sch Dent, Dept Restorat Dent, BR-37130000 Alfenas, MG, Brazil-
dc.description.affiliationUni Sagrado Coracao, Fac Dent, Dept Oral Biol, BR-17011160 Bauru, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Aracatuba, SP, Brazil-
dc.identifier.doi10.1117/1.JBO.19.6.066012-
dc.identifier.wosWOS:000340432900019-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal Of Biomedical Optics-
dc.identifier.orcid0000-0002-3800-3050pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.