You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/117818
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLopes, Sarah Bessi-
dc.contributor.authorCorrea, Cassia Belloto-
dc.contributor.authorAraujo, Cleudmar Amaral de-
dc.contributor.authorVaz, Luis Geraldo-
dc.contributor.authorSilvaGomes, J. F.-
dc.contributor.authorVaz, MAP-
dc.date.accessioned2015-03-18T15:56:58Z-
dc.date.accessioned2016-10-25T20:36:16Z-
dc.date.available2015-03-18T15:56:58Z-
dc.date.available2016-10-25T20:36:16Z-
dc.date.issued2012-01-01-
dc.identifier.citationIcem15: 15th International Conference On Experimental Mechanics. Porto: Inegi-inst Engenharia Mecanica E Gestao Industrial, 2 p., 2012.-
dc.identifier.urihttp://hdl.handle.net/11449/117818-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/117818-
dc.description.abstractOne of the main reasons for the failure in dental implant treatments is the overload, which can cause bone resorption and later, the osseointegration loss in the implant. Therefore, the aim of this study was to analyze the tension generated around dental implants in the rehabilitation of three mandible posterior teeth, varying the connection type, the disposal, and the quantity of implants. The photoelasticity method was used in order to accomplish it. Through photoelasticity, the quantity and localization of the tensions around the implants in the different studied groups were compared (three straight line implants, three offset placement implants, two implants with a mesial cantilever, and two implants with a pontic). The results showed that the tension quantity and disposition around the dental implants of the connection external hexagon and internal hexagon were similar in all groups. In the group where the cantilever was used, an increase of the tension around the implant, adjacent to the cantilever, was observed. From the results it is concluded that the type of connection used in this study did not influence the tension quantity and distribution around the implants; however, the prosthetic configuration with the cantilever use, led to an increase of the tension around the implant, adjacent to the cantilever.en
dc.format.extent2-
dc.language.isoeng-
dc.publisherInegi-inst Engenharia Mecanica E Gestao Industrial-
dc.sourceWeb of Science-
dc.subjectBiomechanicsen
dc.subjectDental Implanten
dc.subjectFhotoelasticity Methoden
dc.titleBIOMECHANICAL BEHAVIOR OF THE SYSTEM PROSTHESIS/DENTAL IMPLANT: ANALYSIS BY THE PHOTOELASTICITY METHODen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationState Univ Sao Paulo Julio de Mesquita Filho, Dent Sch Araraquara, Dept Dent Mat & Prosthet, Sao Paulo, Brazil-
dc.description.affiliationUnespState Univ Sao Paulo Julio de Mesquita Filho, Dent Sch Araraquara, Dept Dent Mat & Prosthet, Sao Paulo, Brazil-
dc.identifier.wosWOS:000320722900090-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIcem15: 15th International Conference On Experimental Mechanics-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.