You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/11891
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMiranda, Diana Rodrigues de Pina-
dc.contributor.authorMorceli, José-
dc.contributor.authorDuarte, Sérgio Barbosa-
dc.contributor.authorGhilardi Netto, Thomaz-
dc.date.accessioned2014-05-20T13:34:38Z-
dc.date.available2014-05-20T13:34:38Z-
dc.date.issued2006-10-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-39842006000500010-
dc.identifier.citationRadiologia Brasileira. Colégio Brasileiro de Radiologia e Diagnóstico por Imagem, v. 39, n. 5, p. 351-354, 2006.-
dc.identifier.issn0100-3984-
dc.identifier.urihttp://hdl.handle.net/11449/11891-
dc.description.abstractOBJETIVO: Este trabalho tem como objetivo a otimização de imagens mamográficas, com consideráveis reduções de doses. MATERIAIS E MÉTODOS: Neste estudo o feixe de raios-X foi calibrado para cada tensão (kVp), de modo a determinar a melhor combinação de kVp e mAs que irá proporcionar uma densidade ótica (DO) em torno de 1.0 acima da base mais véu do filme utilizado. RESULTADOS: Serão discutidas questões sobre os métodos empregados para a seleção de parâmetros de exposição do feixe de raios-X, seleção da melhor imagem utilizando o método de avaliação gradativa visual, comparações entre as doses e carga do tubo (kVp × mAs) proporcionadas pelas técnicas determinadas neste estudo e pelas utilizadas na rotina clínica do Serviço de Diagnóstico por Imagem do Hospital das Clínicas da Faculdade de Medicina de Botucatu. Neste estudo foram obtidas imagens radiográficas de mama de excelente qualidade, com redução de dose e carga de tubo, respectivamente, de 36,8% e 46,2%, quando comparadas com a técnica utilizada pela rotina clínica da instituição. CONCLUSÃO: Esta pesquisa vem contribuir com a otimização da relação risco-benefício para o paciente e custo-benefício para a instituição.pt
dc.description.abstractOBJECTIVE: The aim of this study is the optimization of mammographic images with a considerable radiation dose reduction. MATERIALS and METHODS: In the present study the X-ray beam was calibrated for each tension (kVp), aiming at determining the best combination between kVp and mAs, resulting in optical densities of about 1.0 above the base-plus-fog density. RESULTS: This study will bring into question the methods for X-ray beam calibration, the choice of the best image by means of visual grading analysis, comparisons between doses and tube load (kVp × mAs) delivered by the techniques described in this study and by those adopted in the clinical routine at Service of Diagnostic Imaging of Faculdade de Medicina de Botucatu Clinics Hospital, Botucatu, SP, Brazil. Excellent breast radiographic images have been obtained with doses and tube loads reduction of respectively 36.8% and 46.2% in comparison to those employed in our institutions' clinical routine. CONCLUSION: This study is a contribution to the optimization of the risk-benefit ratio for patients and cost-benefit ratio for the institution.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent351-354-
dc.language.isopor-
dc.publisherColégio Brasileiro de Radiologia e Diagnóstico por Imagem-
dc.sourceSciELO-
dc.subjectMamografiapt
dc.subjectFantoma homogêneopt
dc.subjectControle de qualidadept
dc.subjectRedução de dosept
dc.subjectMammographyen
dc.subjectHomogeneous phantomen
dc.subjectQuality controlen
dc.subjectDose reductionen
dc.titleOtimização de imagens mamográficaspt
dc.title.alternativeOptimization of mammographic imagesen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionCentro Brasileiro de Pesquisas Físicas (CBPF)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUnesp Faculdade de Medicina de Botucatu Departamento de Doenças Tropicais e Diagnóstico por Imagem-
dc.description.affiliationCentro Brasileiro de Pesquisas Físicas-
dc.description.affiliationUniversidade de São Paulo Faculdade de Filosofia, Ciências e Letras da Ribeirão Preto-
dc.description.affiliationUnespUnesp Faculdade de Medicina de Botucatu Departamento de Doenças Tropicais e Diagnóstico por Imagem-
dc.identifier.doi10.1590/S0100-39842006000500010-
dc.identifier.scieloS0100-39842006000500010-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-39842006000500010.pdf-
dc.relation.ispartofRadiologia Brasileira-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.