Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/123538
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chopra, Shilpi | - |
dc.contributor.author | Lima Gomes, Paulo Clairmont Feitosa de | - |
dc.contributor.author | Dhandapani, Ramkumar | - |
dc.contributor.author | Snow, Nicholas H. | - |
dc.date.accessioned | 2015-05-15T13:30:23Z | - |
dc.date.accessioned | 2016-10-25T20:48:39Z | - |
dc.date.available | 2015-05-15T13:30:23Z | - |
dc.date.available | 2016-10-25T20:48:39Z | - |
dc.date.issued | 2014 | - |
dc.identifier | http://www.scientiachromatographica.com/doi/10.4322/sc.2014.024 | - |
dc.identifier.citation | Scientia Chromatographica, v. 6, n. 2, p. 105-116, 2014. | - |
dc.identifier.issn | 1984-4433 | - |
dc.identifier.uri | http://hdl.handle.net/11449/123538 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/123538 | - |
dc.description.abstract | Direct immersion SPME-GC-MS-MS was used for the analysis of steroids in water at part-per-trillion(ppt) and lower concentrations. The method was validated and extended to real sample analysis. The method were linear from 0.01 to 5 ng/ml with precision less than 10% relative standard deviation for a steroid mixture at 1 ng/ml. Limit of quantitation and limit of detection was found to be 200- 1200 pg/L and 30-200 pg/L respectively and recoveries ranged from 88-103 %. To understand the extraction efficiency of the fiber, a depletion study was performed. The fiber/ sample partition coefficients for the steroids were determined to be 1.0 x 104 to 1.5 x 104 . The extraction was performed without derivatization or the use of an internal standard. SPMEGC-MS-MS effectively demonstrated ultra-trace level detection of steroids in water. | en |
dc.format.extent | 105-116 | - |
dc.language.iso | por | - |
dc.source | Currículo Lattes | - |
dc.subject | Steroids using Solid Phase Microextraction | en |
dc.subject | SPME | en |
dc.subject | Gas Chromatography-Mass Spectrometry-Mass Spectrometry | en |
dc.subject | GC-MS-MS | en |
dc.subject | SPMEGC-MS-MS | en |
dc.subject | water analysis | en |
dc.title | Analysis of Steroids using Solid Phase Microextraction-Gas Chromatography-Mass Spectrometry-Mass Spectrometry (SPME-GC-MS-MS) | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, Departamento de Química Analítica, Jardim Quitandinha, CEP 14800060, SP, Brasil | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, Departamento de Química Analítica, Jardim Quitandinha, CEP 14800060, SP, Brasil | - |
dc.identifier.doi | http://dx.doi.org/10.4322/sc.2014.024 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Scientia Chromatographica | - |
dc.identifier.lattes | 0049857977635051 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.