Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/123539
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Toro, Maricely Janette Uria | - |
dc.contributor.author | Marestoni, Luiz Diego | - |
dc.contributor.author | Sotomayor, Maria Del Pilar Taboada | - |
dc.date.accessioned | 2015-05-15T13:30:23Z | - |
dc.date.accessioned | 2016-10-25T20:48:40Z | - |
dc.date.available | 2015-05-15T13:30:23Z | - |
dc.date.available | 2016-10-25T20:48:40Z | - |
dc.date.issued | 2014 | - |
dc.identifier | http://www.sciencedirect.com/science/article/pii/S0925400514014063 | - |
dc.identifier.citation | Sensors and Actuators. B, Chemical, v. 208, p. 299-306, 2014. | - |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | http://hdl.handle.net/11449/123539 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/123539 | - |
dc.description.abstract | A new selective sensor based on molecularly imprinted polymers (MIPs) was developed for the determination of hexazinone (HXZ) in environmental samples. MIPs were synthesized using a non-covalent approach, and selection of the monomers employed in the polymerization reaction was carried out by molecular modeling. Three functional monomers with high (2-vinylpyridine (MP17)) and intermediate (methacrylic acid (MP12) and acrylamide (MP5)) energies of binding to the template (HXZ) were selected for preparation of the MIPs, in order to conduct comparative studies and validate the theoretical data. For sensor construction, carbon pastes were modified with each MIP or NIP (non-imprinted polymer), and HXZ determination was performed using differential pulse adsorptive cathodic stripping voltammetry (DPAdCSV). All parameters affecting the sensor response were optimized. In HCl at pH 2.5, the sensor prepared with MP17 (5% w/w in the paste) showed a dynamic linear range between 1.9 × 10−11 and 1.1 × 10−10 mol L−1, and a detection limit of 2.6 × 10−12 mol L−1, under the following conditions: accumulation time of 200 s at a potential of −0.5V, scan rate of 50 mVs−1, pulse amplitude of 60 mV, and pulse width of 50 ms. The sensor was selective in the presence of other similar compounds, and was successfully applied to the analysis of HXZ in river water samples. | en |
dc.format.extent | 299-306 | - |
dc.language.iso | eng | - |
dc.source | Currículo Lattes | - |
dc.subject | 1,3,5-Triazine | en |
dc.subject | Hexazinone | en |
dc.subject | Molecularly imprinted polymer | en |
dc.subject | Carbon paste sensor | en |
dc.subject | Molecular modeling | en |
dc.title | A new biomimetic sensor based on molecularly imprinted polymers for highly sensitive and selective determination of hexazinone herbicide | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Instituto de Química de Araraquara, Araraquara, Rua Professor Francisco Degni, 55, Jardim Quitandinha, CEP 14800060, SP, Brasil | - |
dc.description.affiliationUnesp | Department of Analytical Chemistry, Institute of Chemistry, State University of São Paulo (UNESP), 14801-970 Araraquara, SP, Brazil | - |
dc.identifier.doi | http://dx.doi.org/10.1016/j.snb.2014.11.036 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Sensors and Actuators. B, Chemical | - |
dc.identifier.lattes | 2933194342093387 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.