Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/125640
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oliveira, Matheus Lima de | - |
dc.contributor.author | Tosoni, Guilherme Monteiro | - |
dc.contributor.author | Lindsey, David H. | - |
dc.contributor.author | Mendoza, Kristopher Anthony | - |
dc.contributor.author | Tetradis, Sotirios | - |
dc.contributor.author | Mallya, Sanjay M. | - |
dc.date.accessioned | 2015-08-06T16:12:41Z | - |
dc.date.accessioned | 2016-10-25T20:53:21Z | - |
dc.date.available | 2015-08-06T16:12:41Z | - |
dc.date.available | 2016-10-25T20:53:21Z | - |
dc.date.issued | 2014 | - |
dc.identifier | http://synapse.koreamed.org/DOIx.php?id=10.5624/isd.2014.44.4.279 | - |
dc.identifier.citation | Imaging Science in Dentistry, v. 44, n. 4, p. 279-285, 2014. | - |
dc.identifier.issn | 2233-7822 | - |
dc.identifier.uri | http://hdl.handle.net/11449/125640 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/125640 | - |
dc.description.abstract | To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K2HPO4 solutions were measured. The relationship between CT number and K2HPO4 concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results The relationship between K2HPO4 concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship. | en |
dc.format.extent | 279-285 | - |
dc.language.iso | eng | - |
dc.source | Currículo Lattes | - |
dc.subject | Cone-Beam Computed Tomography | en |
dc.subject | Image Processing | en |
dc.subject | Computer-Assisted | en |
dc.subject | Imaging | en |
dc.subject | Three-Dimensional | en |
dc.title | Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | University of California | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.description.affiliation | Section of Oral and Maxillofacial Radiology | - |
dc.description.affiliation | Department of Oral Diagnosis | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Diagnóstico e Cirurgia, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, 1680, Centro, CEP 14801903, SP, Brasil | - |
dc.identifier.doi | http://dx.doi.org/10.5624/isd.2014.44.4.279 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Imaging Science in Dentistry | - |
dc.identifier.lattes | 0692567697594977 | - |
dc.identifier.lattes | 3156969817236677 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.