Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/126136
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oliveira, G. J. P. de | - |
dc.contributor.author | Macedo, P. D. |Tsurumaki J. N. | - |
dc.contributor.author | Sampaio, J. E. | - |
dc.contributor.author | Marcantonio, Rosemary Adriana Chierici | - |
dc.date.accessioned | 2015-08-06T16:14:03Z | - |
dc.date.accessioned | 2016-10-25T20:54:28Z | - |
dc.date.available | 2015-08-06T16:14:03Z | - |
dc.date.available | 2016-10-25T20:54:28Z | - |
dc.date.issued | 2015 | - |
dc.identifier | http://onlinelibrary.wiley.com/doi/10.1111/idh.12134/abstract | - |
dc.identifier.citation | International Journal of Dental Hygiene, v. 2, n. 3, p. 1-7, 2015. | - |
dc.identifier.issn | 1601-5029 | - |
dc.identifier.uri | http://hdl.handle.net/11449/126136 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/126136 | - |
dc.description.abstract | To evaluate the influence of variations in the working angle of the piezoelectric ultrasonic scaler (PUS) on root surfaces. Material and methods Fifty-five uniradicular bovine teeth were used, of which 25 teeth were used for the analysis of the roughness and root wear, while the remaining 30 teeth were used for the analysis of morphology (MRS) and the attachment of blood components (ABC). The teeth were randomly divided into five groups according to the type of treatment (G1-G5: piezoelectric ultrasonic scaler; G6: manual curette) and to the PUS working angle applied (G1: 0°; G2: 30°; G3: 45°; G4: 60°; G5: 90°). For statistical analysis, the data describing the MRS and ABC were analysed by the Kruskal–Wallis and Dunn's tests, and the data describing the roughness and tooth wear were analysed by anova and Tukey's tests at the significance level of 5%. Results Manual curette (MC) promoted a smoother root surface than the application of the PUS. The PUS used at the angles of 30° and 45° resulted in a high level of ABC that was comparable to that obtained by MC. Additionally, the group in which the PUS was applied at an angle of 45° exhibited less tooth wear than the other groups. Conclusions Changes in the working angle of the PUS influenced the characteristics of root surfaces after instrumentation. | en |
dc.format.extent | 1-7 | - |
dc.language.iso | eng | - |
dc.source | Currículo Lattes | - |
dc.subject | Periodontitis | en |
dc.subject | Scanning electron microscopy | en |
dc.subject | Tooth wear | en |
dc.subject | Ultrasonics | en |
dc.title | The effect of the angle of instrumentation of the piezoelectric ultrasonic scaler on root surfaces | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, RUA HUMAITÁ Nº 1680, CENTRO, CEP 14801-903, SP, Brasil | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, RUA HUMAITÁ Nº 1680, CENTRO, CEP 14801-903, SP, Brasil | - |
dc.identifier.doi | http://dx.doi.org/10.1111/idh.12134 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | International Journal of Dental Hygiene | - |
dc.identifier.lattes | 9531839078426485 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.