You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/12773
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRibeiro, D. A.-
dc.contributor.authorMarques, Mariângela Esther Alencar-
dc.contributor.authorSalvadori, Daisy Maria Favero-
dc.date.accessioned2014-05-20T13:37:02Z-
dc.date.accessioned2016-10-25T16:53:52Z-
dc.date.available2014-05-20T13:37:02Z-
dc.date.available2016-10-25T16:53:52Z-
dc.date.issued2006-12-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1365-2842.2006.01658.x-
dc.identifier.citationJournal of Oral Rehabilitation. Oxford: Blackwell Publishing, v. 33, n. 12, p. 912-917, 2006.-
dc.identifier.issn0305-182X-
dc.identifier.urihttp://hdl.handle.net/11449/12773-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/12773-
dc.description.abstractGlass-ionomer cements are widely used in dentistry as restorative materials and adhesives for composite restorations. A number of genotoxicity studies have been conducted using these materials with results conflicting so far. Thus, the approach was aimed to look at the genotoxic and cytotoxic potential of three different glass-ionomer cements available commercially (Ketac Cem, Ketac Molar and Vitrebond) by the single cell gel (comet) assay and trypan blue exclusion test, respectively. For this, such materials were exposed to mouse lymphoma cells in vitro for 1 h at 37 degrees C. Data were assessed by Kruskall-Wallis non-parametric test. The results showed that all powders assayed did not show genotoxic effects. on the other hand, the liquid from Vitrebond at 0.1% dilution caused an increase of DNA injury. Significant statistically differences (P < 0.05) in cytotoxicity provoked by all powders tested were observed for exposure at 1000 mu g mL(-1) concentration and 100 mu g mL(-1) for Ketac Molar. With respect to liquids of glass-ionomer cements evaluated, the major toxic effect on cell viability was produced at 1%, beginning at the dilution of 0.5% for Vitrebond. Taken together, these results support the notion that some components of glass-ionomer cements show both genotoxic and cytotoxic effects in higher concentrations.en
dc.format.extent912-917-
dc.language.isoeng-
dc.publisherBlackwell Publishing-
dc.sourceWeb of Science-
dc.subjectcytotoxicitypt
dc.subjectgenotoxicitypt
dc.subjectglass-ionomer cementspt
dc.subjectmouse lymphoma cellspt
dc.titleBiocompatibility of glass-ionomer cements using mouse lymphoma cells in vitroen
dc.typeoutro-
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Fed São Paulo, Dept Hlth Sci, São Paulo, Brazil-
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Botucatu Med Sch, TOXICAN, Ctr Genotoxins & Carcinogens Evaluat,Dept Pathol, Botucatu, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Botucatu Med Sch, TOXICAN, Ctr Genotoxins & Carcinogens Evaluat,Dept Pathol, Botucatu, SP, Brazil-
dc.identifier.doi10.1111/j.1365-2842.2006.01658.x-
dc.identifier.wosWOS:000242235400006-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Oral Rehabilitation-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.