You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/128579
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAlves, Allan Felipe Fattori-
dc.contributor.authorMiranda, José Ricardo de Arruda-
dc.contributor.authorBacchim Neto, Fernando Antonio-
dc.contributor.authorDuarte, Sergio Barbosa-
dc.contributor.authorPina, Diana Rodrigues de-
dc.date.accessioned2015-10-21T13:11:10Z-
dc.date.accessioned2016-10-25T20:59:57Z-
dc.date.available2015-10-21T13:11:10Z-
dc.date.available2016-10-25T20:59:57Z-
dc.date.issued2015-08-01-
dc.identifierhttp://www.sciencedirect.com/science/article/pii/S0720048X15002430-
dc.identifier.citationEuropean Journal Of Radiology. Clare: Elsevier Ireland Ltd, v. 84, n. 8, p. 1579-1585, 2015.-
dc.identifier.issn0720-048X-
dc.identifier.urihttp://hdl.handle.net/11449/128579-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/128579-
dc.description.abstractObjectives: To develop two pediatric patient-equivalent phantoms, the Pediatric Chest Equivalent Patient (PCEP) and the Pediatric Skull Equivalent Patient (PSEP) for children aged Ito 5 years. We also used both phantoms for image quality evaluations in computed radiography systems to determine Gold Standard (GS) techniques for pediatric patients.Methods: To determine the simulator materials thickness (Lucite and aluminum), we quantified biological tissues (lung, soft, and bone) using an automatic computational algorithm. To objectively establish image quality levels, two physical quantities were used: effective detective quantum efficiency and contrastto-noise ratio. These quantities were associated to values obtained for standard patients from previous studies.Results: For chest radiographies, the GS technique applied was 81 kVp, associated to 2.0 mAs and 83.6 tiGy of entrance skin dose (ESD), while for skull radiographies, the GS technique was 70 kVp, associated to 5 mAs and 339 tiGy of ESD.Conclusion: This procedure allowed us to choose optimized techniques for pediatric protocols, thus improving quality of diagnosis for pediatric population and reducing diagnostic costs to our institution. These results could also be easily applied to other services with different equipment technologies. (C) 2015 Elsevier Ireland Ltd. All rights reserved.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent1579-1585-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectChest and skullen
dc.subjectPediatric homogenous phantomen
dc.subjectImage qualityen
dc.subjectDose optimizationen
dc.titleConstruction of pediatric homogeneous phantoms for optimization of chest and skull radiographsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionCentro Brasileiro de Pesquisas Físicas-
dc.description.affiliationCentro Brasileiro de Pesquisas Físicas, Laboratório de Altas Energias, Dr. Xavier Sigaud, 150, Rio de Janeiro, 22290-180 Rio de Janeiro, Brazil-
dc.description.affiliationUnespInstituto de Biociências de Botucatu, P.O. BOX 510, Departamento de Física e Biofísica, UNESP—Universidade Estadual Paulista, Distrito de Rubião Junior S/N, Botucatu, 18618-000 São Paulo, Brazil-
dc.description.affiliationUnespDepartamento de Doenças Tropicais e Diagnóstico por Imagem, Faculdade de Medicina de Botucatu, UNESP—Universidade Estadual Paulista, Distrito de Rubião Junior S/N, Botucatu, 18618-000 São Paulo, Brazil-
dc.description.affiliationUnespInstituto de Biociências de Botucatu, Departamento de Física e Biofísica, UNESP—Universidade Estadual Paulista, Distrito de Rubião Junior S/N, Botucatu, 18618-000 São Paulo, Brazil.-
dc.identifier.doihttp://dx.doi.org/10.1016/j.ejrad.2015.05.015-
dc.identifier.wosWOS:000357474200023-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofEuropean Journal Of Radiology-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.