You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/128850
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMarafão, Fernando Pinhabel-
dc.contributor.authorBrandão, Danilo Iglesias-
dc.contributor.authorCostabeber, Alessandro-
dc.contributor.authorMorales Paredes, Helmo Kelis-
dc.date.accessioned2015-10-21T13:14:27Z-
dc.date.accessioned2016-10-25T21:00:36Z-
dc.date.available2015-10-21T13:14:27Z-
dc.date.available2016-10-25T21:00:36Z-
dc.date.issued2015-03-01-
dc.identifierhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7046284-
dc.identifier.citationIet Renewable Power Generation. Hertford: Inst Engineering Technology-iet, v. 9, n. 2, p. 154-165, 2015.-
dc.identifier.issn1752-1416-
dc.identifier.urihttp://hdl.handle.net/11449/128850-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/128850-
dc.description.abstractln recent years, the concept of decentralising power generation through the deployment of distributed generators (DGs) has been widely accepted and applied, driven by the growing market of renewable energy sources. These DGs are normally equipped with a switching power interface, acting as front end with the grid. This paper proposes a multi-task control strategy for distributed generation systems that simultaneously allows the DG to inject the available energy, as well as to work as a voltage drop compensator or as an active power filter, mitigating load current disturbances and improving power quality of the grid. The main contribution of the proposed system, with respect to other solutions in the literature, is that the proposed control loops are based on the Conservative Power Theory decompositions. This choice provides decoupled power and current references for the inverter control, offering a very flexible, selective and powerful control strategy for the DG. The paper also discusses the choice of the current waveform for injecting/absorbing active power into/from the grid, and both sinusoidal and resistive references have been compared in terms of damping capability. Finally, simulation and experimental results are provided in order to validate the proposed functionalities of the DG control system.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipFundação para o Desenvolvimento da UNESP (FUNDUNESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent154-165-
dc.language.isoeng-
dc.publisherInst Engineering Technology-iet-
dc.sourceWeb of Science-
dc.titleMulti-task control strategy for grid-tied inverters based on conservative power theoryen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)-
dc.contributor.institutionUniversity of Nottingham-
dc.description.affiliationDepartment of System and Energy, University of Campinas, Av. Albert Eintein 400, Campinas, SP, Brazil-
dc.description.affiliationDepartment of Electrical and Electronic Engineering, University of Nottingham, NG7 2RD, Nottingham, NG, UK-
dc.description.affiliationUnespUNESP–Universidade Estadual Paulista, Av. Três de Março 511, Sorocaba, SP, Brazil, Group of Automation and Integrated Systems-
dc.description.sponsorshipIdFAPESP: 2012/24309-8-
dc.description.sponsorshipIdFAPESP: 2012/14014-0-
dc.description.sponsorshipIdFAPESP: 2013/08545-6-
dc.description.sponsorshipIdCNPq: 487471/2012-1-
dc.description.sponsorshipIdCNPq: 554960/2006-0-
dc.identifier.doihttp://dx.doi.org/10.1049/iet-rpg.2014.0065-
dc.identifier.wosWOS:000350212100007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofIet Renewable Power Generation-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.