Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/128907
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorOliveira de Vasconcellos, Luis Gustavo-
dc.contributor.authorKojima, Alberto Noriyuki-
dc.contributor.authorNishioka, Renato Sussumu-
dc.contributor.authorReis de Vasconcellos, Luana Marotta-
dc.contributor.authorBalducci, Ivan-
dc.date.accessioned2015-10-21T13:15:25Z-
dc.date.accessioned2016-10-25T21:06:26Z-
dc.date.available2015-10-21T13:15:25Z-
dc.date.available2016-10-25T21:06:26Z-
dc.date.issued2015-04-01-
dc.identifierhttp://www.joionline.org/doi/10.1563/AAID-JOI-D-10-00174-
dc.identifier.citationJournal Of Oral Implantology. Lawrence: Allen Press Inc, v. 41, n. 2, p. 149-154, 2015.-
dc.identifier.issn0160-6972-
dc.identifier.urihttp://hdl.handle.net/11449/128907-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/128907-
dc.description.abstractThe aim of this in vitro study was to use strain gauge (SG) analysis to compare the effects of the implant-abutment joint, the coping, and the location of load on strain distribution in the bone around implants supporting 3-unit fixed partial prostheses. Three external hexagon (EH) implants and 3 internal hexagon (IH) implants were inserted into 2 polyurethane blocks. Microunit abutments were screwed onto their respective implant groups. Machined cobalt-chromium copings and plastic copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in a cobalt-chromium alloy (n = 5): group 1 = EH/machined. group 2 = EH/plastic, group 3 = IH/machined, and group 4 = IH/plastic. Four SGs were bonded onto the surface of the block tangentially to the implants. Each metallic structure was screwed onto the abutments and an axial load of 30 kg was applied at 5 predetermined points. The magnitude of microstrain on each SG was recorded in units of microstrain (mu epsilon). The data were analyzed using 3-factor repeated measures analysis of variance and a Tukey test (alpha = 0.05). The results showed statistically significant differences for the type of implant-abutment joint, loading point, and interaction at the implant-abutment joint/loading point. The IH connection showed higher microstrain values than the EH connection. It was concluded that the type of coping did not interfere in the magnitude of microstrain, but the implant/abutment joint and axial loading location influenced this magnitude.en
dc.format.extent149-154-
dc.language.isoeng-
dc.publisherAllen Press Inc-
dc.sourceWeb of Science-
dc.subjectBiomechanicsen
dc.subjectDental implantsen
dc.subjectDental prosthesisen
dc.subjectImplant-supported dental prosthesisen
dc.titleAxial loads on implant-supported partial fixed prostheses for external and internal hex connections and machined and plastic copings: strain gauge analysisen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia (ICT), Departamento de Materiais Odontológicos e Prótese, São José dos Campos, SP, Brasil-
dc.description.affiliationUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia (ICT), Departamento de Biociências e Diagnóstico Bucal, São José dos Campos, SP, Brasil-
dc.description.affiliationUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia (ICT), Departamento de Odontologia Social e Clínica Infantil, São José dos Campos, SP, Brasil-
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia (ICT), Departamento de Materiais Odontológicos e Prótese, São José dos Campos, SP, Brasil-
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia (ICT), Departamento de Biociências e Diagnóstico Bucal, São José dos Campos, SP, Brasil-
dc.description.affiliationUnespUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia (ICT), Departamento de Odontologia Social e Clínica Infantil, São José dos Campos, SP, Brasil-
dc.identifier.doihttp://dx.doi.org/10.1563/AAID-JOI-D-10-00174-
dc.identifier.wosWOS:000353303000014-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal Of Oral Implantology-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.