You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/129099
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPetruci, João Flavio da Silveira-
dc.contributor.authorCardoso, Arnaldo Alves-
dc.date.accessioned2015-10-21T20:21:55Z-
dc.date.accessioned2016-10-25T21:08:21Z-
dc.date.available2015-10-21T20:21:55Z-
dc.date.available2016-10-25T21:08:21Z-
dc.date.issued2015-01-01-
dc.identifierhttp://pubs.rsc.org/en/Content/ArticleLanding/2015/AY/C4AY02952F-
dc.identifier.citationAnalytical Methods. Cambridge: Royal Soc Chemistry, v. 7, n. 6, p. 2687-2692, 2015.-
dc.identifier.issn1759-9660-
dc.identifier.urihttp://hdl.handle.net/11449/129099-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/129099-
dc.description.abstractH2S is an extremely malodorous, toxic and corrosive gas. These properties make the localized emission of hydrogen sulfide an air pollution issue. Despite there being a relatively large number of papers in literature dedicated to developing analytical methods to determine gaseous H2S, it remains an analytical problem. In this paper, we describe a luminescent cellulose filter-based sensor for gaseous H2S determination. The cellulose filter is impregnated with a palladium complex, containing a ligand with fluorescent properties. The measurements are made directly on the cellulose filter, and thus do not require an extraction step. The palladium complex - bis(2-aminobenzoic)palladium(II) - impregnated on the surface of the cellulose filter paper reacts with gaseous H2S. The reaction results in the release of the fluorescent ligand, increasing the fluorescence intensity of the filter surface observed at 410 nm when excited at 338 nm. The linear calibration curve covers the range from 8 to 110 ppb, with a limit of detection (LOD) of 2 ppb. The sampling time is approximately 15 min for this range of H2S; however, a longer sampling may decrease the detection limit. The factors affecting the collection characteristics, such as sampling flow, media moisture, cellulose filter paper type and amount of humectant (ethylene glycol) in the impregnating solution amount, were optimized.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent2687-2692-
dc.language.isoeng-
dc.publisherRoyal Soc Chemistry-
dc.sourceWeb of Science-
dc.titleSensitive luminescent paper-based sensor for the determination of gaseous hydrogen sulfideen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUnespUniversidade Estadual Paulista, Departamento de Química Analítica, Instituto de Química de Araraquara-
dc.description.sponsorshipIdFAPESP: 2013/22995-4-
dc.identifier.doihttp://dx.doi.org/10.1039/c4ay02952f-
dc.identifier.wosWOS:000351391800061-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalytical Methods-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.