dc.contributor.author | Rossi, Jose Carlos | - |
dc.contributor.author | Oliveira, Luis Carlos Origa de | - |
dc.contributor.author | Ferreira, Marco A S | - |
dc.date.accessioned | 2014-05-27T11:19:49Z | - |
dc.date.accessioned | 2016-10-25T21:21:48Z | - |
dc.date.available | 2014-05-27T11:19:49Z | - |
dc.date.available | 2016-10-25T21:21:48Z | - |
dc.date.issued | 1999-12-01 | - |
dc.identifier | http://dx.doi.org/10.1109/MWSCAS.1999.867740 | - |
dc.identifier.citation | MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, 42., Proceedings..., Vols 1 and 2. New York: IEEE, p. 727-730, 1999. | - |
dc.identifier.uri | http://hdl.handle.net/11449/130692 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/130692 | - |
dc.description.abstract | In this work it is discussed the performance of the reactive power demand in three-leg transformer core and three-phase transformer bank, under different conditions of AC/DC double excitation. In order to analyse the influence of double excitation in reactive power theoretically a mathematical model was developed considering the mutual coupling between phases and the magnetic nonlinearity. The validity of the proposed model is verified by means of the experimental and simulated results. | en |
dc.format.extent | 727-730 | - |
dc.language.iso | eng | - |
dc.publisher | IEEE | - |
dc.source | Scopus | - |
dc.subject | Approximation theory | - |
dc.subject | Computer simulation | - |
dc.subject | Electric currents | - |
dc.subject | Electric excitation | - |
dc.subject | Electric resistance | - |
dc.subject | Magnetic circuits | - |
dc.subject | Magnetization | - |
dc.subject | Mathematical models | - |
dc.subject | Reactive power | - |
dc.subject | Leakage inductance | - |
dc.subject | Magnetic nonlinearity | - |
dc.subject | Three phase transformer | - |
dc.subject | Transformer bank | - |
dc.subject | Electric transformers | - |
dc.title | Influence of double excitation AC/DC in the reactive power demand of 3-phase transformers | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, DEE, FEIS, Ilha Solteira, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, DEE, FEIS, Ilha Solteira, SP, Brazil | - |
dc.identifier.doi | 10.1109/MWSCAS.1999.867740 | - |
dc.identifier.wos | WOS:000089525800174 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Midwest Symposium on Circuits and Systems | - |
dc.identifier.scopus | 2-s2.0-0033292526 | - |