You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/130982
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCoelho Goiato, Marcelo-
dc.contributor.authorPesqueira, Alves Aldiéris-
dc.contributor.authorSantos, Daniela Micheline Dos-
dc.contributor.authorHaddad, Marcela Filié-
dc.contributor.authorMoreno, Amália-
dc.date.accessioned2015-12-07T15:30:35Z-
dc.date.accessioned2016-10-25T21:22:27Z-
dc.date.available2015-12-07T15:30:35Z-
dc.date.available2016-10-25T21:22:27Z-
dc.date.issued2014-
dc.identifierhttp://dx.doi.org/10.7860/JCDR/2014/8489.4902-
dc.identifier.citationJournal Of Clinical And Diagnostic Research : Jcdr, v. 8, n. 9, p. 86-90, 2014.-
dc.identifier.issn2249-782X-
dc.identifier.urihttp://hdl.handle.net/11449/130982-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/130982-
dc.description.abstractThis study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.en
dc.format.extent86-90-
dc.language.isoeng-
dc.sourcePubMed-
dc.subjectBiomechanicalen
dc.subjectDental implantationen
dc.subjectDental stress analysisen
dc.titlePhotoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wideen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationAdjunct Professor, Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University -UNESP, Araçatuba, São Paulo, Brazil .-
dc.description.affiliationAssociate Professor, Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University-UNESP , Araçatuba, São Paulo, Brazil .-
dc.description.affiliationAssociate Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP , Araçatuba, São Paulo, Brazil .-
dc.description.affiliationAdjunct Professor, Federal University of Department of Dental Materials and Prosthodontics , Alfenas - UNIFAL .-
dc.description.affiliationPost-Graduate Student, Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University-UNESP , Araçatuba, São Paulo, Brazil .-
dc.description.affiliationUnespAdjunct Professor, Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University -UNESP, Araçatuba, São Paulo, Brazil .-
dc.description.affiliationUnespAssociate Professor, Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University-UNESP , Araçatuba, São Paulo, Brazil .-
dc.description.affiliationUnespAssociate Professor, Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP , Araçatuba, São Paulo, Brazil .-
dc.description.affiliationUnespPost-Graduate Student, Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University-UNESP , Araçatuba, São Paulo, Brazil .-
dc.identifier.doi10.7860/JCDR/2014/8489.4902-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal Of Clinical And Diagnostic Research : Jcdr-
dc.identifier.orcid0000-0002-3800-3050pt
dc.identifier.pubmed25386531-
dc.identifier.pmcPMC4225983-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.