Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/131324
Registro de metadados completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Zocolo, Guilherme Julião | - |
dc.contributor.author | Pilon dos Santos, Glauco | - |
dc.contributor.author | Vendemiatti, Josiane | - |
dc.contributor.author | Vacchi, Francine Inforçato | - |
dc.contributor.author | Umbuzeiro, Gisela de Aragão | - |
dc.contributor.author | Zanoni, Maria Valnice Boldrin | - |
dc.date.accessioned | 2015-12-07T15:33:53Z | - |
dc.date.accessioned | 2016-10-25T21:23:15Z | - |
dc.date.available | 2015-12-07T15:33:53Z | - |
dc.date.available | 2016-10-25T21:23:15Z | - |
dc.date.issued | 2015 | - |
dc.identifier | http://dx.doi.org/10.1093/chromsci/bmu221 | - |
dc.identifier.citation | Journal Of Chromatographic Science, v. 53, n. 8, p. 1257-1264, 2015. | - |
dc.identifier.issn | 1945-239X | - |
dc.identifier.uri | http://hdl.handle.net/11449/131324 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/131324 | - |
dc.description.abstract | We have optimized an SPE-LC-ESI-MS/MS method and used it to monitor disperse azo dyes in environmental aquatic samples. Calibration curves constructed for nine disperse dyes-Red 1, Violet 93, Blue 373, Orange 1, Orange 3, Orange 25, Yellow 3, Yellow 7 and Red 13-in aqueous solution presented good linearity between 2.0 and 100.0 ng mL(-1). The method provided limits of detection and quantification around 2.0 and 8.0 ng L(-1), respectively. For dyes at concentrations of 25.0 ng mL(-1), the intra- and interday analyses afforded relative standard deviation lower than 6 and 13%, respectively. The recovery values obtained for each target analyte in Milli-Q water, receiving waters and treated water samples spiked with the nine studied dyes at concentrations of 8.0, 25.0 and 50.0 ng L(-1) (n = 3) gave average recoveries greater than 70%, with RSD <20%. Statistical evaluation aided method validation. The validated method proved to be useful for analysis of organic extracts from effluents and receiving water samples after an SPE extraction step. More specifically, the method enabled detection of the dyes Disperse Red 1, Disperse Blue 373 and Disperse Violet 93 at concentrations ranging from 84 to 3452 ng L(-1) in the treated effluent (TE), affluent and points collected upstream and downstream of the drinking water treatment plant of a textile dye industry in Brazil. | en |
dc.format.extent | 1257-1264 | - |
dc.language.iso | eng | - |
dc.publisher | Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com. | - |
dc.source | PubMed | - |
dc.title | Using SPE-LC-ESI-MS/MS analysis to assess disperse dyes in environmental water samples | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Electroanalytical Chemistry Laboratory, Department of Analytical Chemistry, UNESP, University of São Paulo State, Araraquara, SP, Brazil gjzocolo@yahoo.com.br. | - |
dc.description.affiliation | Electroanalytical Chemistry Laboratory, Department of Analytical Chemistry, UNESP, University of São Paulo State, Araraquara, SP, Brazil. | - |
dc.description.affiliation | Ecotoxicology and Environmental Microbiology Laboratory, LEAL, School of Technology, University of Campinas, Limeira, SP, Brazil. | - |
dc.description.affiliation | Faculty of Pharmaceutical Sciences, University of São Paulo, São Paulo, SP, Brazil. | - |
dc.description.affiliationUnesp | Electroanalytical Chemistry Laboratory, Department of Analytical Chemistry, UNESP, University of São Paulo State, Araraquara, SP, Brazil gjzocolo@yahoo.com.br. | - |
dc.description.affiliationUnesp | Electroanalytical Chemistry Laboratory, Department of Analytical Chemistry, UNESP, University of São Paulo State, Araraquara, SP, Brazil. | - |
dc.identifier.doi | 10.1093/chromsci/bmu221 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal Of Chromatographic Science | - |
dc.identifier.orcid | 0000-0002-2296-1393 | - |
dc.identifier.pubmed | 25637135 | - |
Aparece nas coleções: | Artigos, TCCs, Teses e Dissertações da Unesp |
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.