Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/131499
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Taylor, Polly M. | - |
dc.contributor.author | Crosignani, Nadia | - |
dc.contributor.author | Lopes, Carlize | - |
dc.contributor.author | Rosa, Ademir C. | - |
dc.contributor.author | Luna, Stelio P. | - |
dc.contributor.author | Puoli Filho, José N. | - |
dc.date.accessioned | 2015-12-07T15:36:29Z | - |
dc.date.accessioned | 2016-10-25T21:23:40Z | - |
dc.date.available | 2015-12-07T15:36:29Z | - |
dc.date.available | 2016-10-25T21:23:40Z | - |
dc.date.issued | 2015-05-21 | - |
dc.identifier | http://dx.doi.org/10.1111/vaa.12274 | - |
dc.identifier.citation | Veterinary Anaesthesia And Analgesia, p. 1-10, 2015. | - |
dc.identifier.issn | 1467-2995 | - |
dc.identifier.uri | http://hdl.handle.net/11449/131499 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/131499 | - |
dc.description.abstract | To examine the relationship between probe tip size and force readings of mechanical nociceptive thresholds (MTs) to identify appropriate probes for horses. Randomized, crossover study. Eight adult, mixed-breed horses aged 5-10 years, weighing 268-460 kg. Four probe configurations (PCs) were used in random sequence: 1.0 mm diameter (SHARP); 3.2 mm (BLUNT); spring-mounted 1.0 mm (SPRING), and 3 × 2.5 mm (3PIN). A remote-controlled unit on the horse increased force (1.2 N second(-1) ) in a pneumatic actuator on the metacarpus. Mean MT for each PC was calculated from 10 readings for each horse. Data were log-transformed for analysis using mixed-effects anova/linear regression (p < 0.05). Variability of data for each PC was assessed using the coefficient of variation (CV). Mean ± standard deviation MTs were: SHARP, 5.6 ± 2.3 N; BLUNT, 11.4 ± 3.4 N; 3PIN, 9.6 ± 4.6 N, and SPRING 6.4 ± 1.8 N. Mean MT for SHARP was significantly lower than for BLUNT (p < 0.001) and 3PIN (p < 0.001), but not different from SPRING (p > 0.05). Mean MT was significantly higher for BLUNT than for 3PIN (p < 0.05) and SPRING (p < 0.001). Mean MT for 3PIN was significantly higher than for SPRING (p < 0.001). Larger contact area PCs produced higher MTs than smaller PCs, but the relationship was not linear. BLUNT (area: 10-fold greater) gave a MT two-fold higher than SHARP. 3PIN (area: 20-fold greater) produced more variable MTs, less than two-fold higher than SHARP. SPRING was similar to SHARP. CVs were: SHARP, 22.9%; BLUNT, 72.3%; 3PIN, 44.2%, and SPRING, 28.7%. The PC has nonlinear effects on MT. Therefore, it is important to define PC when measuring MT. Smaller probe tips may be preferable as MT data are less variable. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.format.extent | 1-10 | - |
dc.language.iso | eng | - |
dc.publisher | Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia | - |
dc.source | PubMed | - |
dc.subject | Force | en |
dc.subject | Nociception | en |
dc.subject | Pain | en |
dc.subject | Pressure | en |
dc.subject | Probe size | en |
dc.subject | Stimulus intensity | en |
dc.title | Mechanical nociceptive thresholds using four probe configurations in horses | en |
dc.type | outro | - |
dc.contributor.institution | Topcat Metrology Ltd | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Topcat Metrology Ltd, Ely, UK. | - |
dc.description.affiliation | Department of Veterinary Surgery and Anesthesiology, Faculty of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu, SP, Brazil. | - |
dc.description.affiliationUnesp | Department of Veterinary Surgery and Anesthesiology, Faculty of Veterinary Medicine and Animal Science, São Paulo State University (UNESP), Botucatu, SP, Brazil. | - |
dc.description.sponsorshipId | FAPESP: 2010/08967-0 | - |
dc.identifier.doi | 10.1111/vaa.12274 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Veterinary Anaesthesia And Analgesia | - |
dc.identifier.orcid | 0000-0001-5312-9076 | pt |
dc.identifier.pubmed | 25997162 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.