Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/134743
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bueno, Atila Madureira | - |
dc.contributor.author | Balthazar, José Manoel | - |
dc.contributor.author | Piqueira, José Roberto Castilho | - |
dc.date.accessioned | 2016-03-02T12:58:12Z | - |
dc.date.accessioned | 2016-10-25T21:31:05Z | - |
dc.date.available | 2016-03-02T12:58:12Z | - |
dc.date.available | 2016-10-25T21:31:05Z | - |
dc.date.issued | 2011 | - |
dc.identifier | http://www.cmsim.eu/journal_issues.html | - |
dc.identifier.citation | Journal of Chaotic Modeling and Simulation, v. 1, p. 176-186, 2011. | - |
dc.identifier.issn | 2241-0503 | - |
dc.identifier.uri | http://hdl.handle.net/11449/134743 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/134743 | - |
dc.description.abstract | The Frequency Modulated - Atomic Force Microscope (FM-AFM) is apowerful tool to perform surface investigation with true atomic resolution. The controlsystem of the FM-AFM must keep constant both the frequency and amplitude ofoscillation of the microcantilever during the scanning process of the sample. However,tip and sample interaction forces cause modulations in the microcantilever motion.A Phase-Locked Loop (PLL) is used as a demodulator and to generate feedback signalto the FM-AFM control system. The PLL performance is vital to the FM-AFMperformace since the image information is in the modulated microcantilever motion.Nevertheless, little attention is drawn to PLL performance in the FM-AFM literature.Here, the FM-AFM control system is simulated, comparing the performancefor di erent PLL designs. | en |
dc.format.extent | 176-186 | - |
dc.language.iso | eng | - |
dc.source | Currículo Lattes | - |
dc.subject | Frequency Modulated Atomic Force Microscope | en |
dc.subject | Phase-Locked Loops | en |
dc.subject | Synchronization | en |
dc.title | Simulations of the Frequency Modulated Atomic Force Microscope (FM-AFM) nonlinear control system | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Escola Politécnica da Universidade de São Paulo | - |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Estatística, Matemática Aplicada e Computacional, Instituto de Geociências e Ciências Exatas de Rio Claro, Rio Claro, Avenida 24A. 1515., Bela Vista, CEP 13506-700, SP, Brasil | - |
dc.description.affiliation | Escola Politécnica, Universidade de São Paulo, Av. Prof. Luciano Gualberto, travessa 3, n. 158, 05508-900, São Paulo, SP, Brazil | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Estatística, Matemática Aplicada e Computacional, Instituto de Geociências e Ciências Exatas de Rio Claro, Rio Claro, Avenida 24A. 1515., Bela Vista, CEP 13506-700, SP, Brasil | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Chaotic Modeling and Simulation | - |
dc.identifier.lattes | 9728054402919622 | - |
dc.identifier.lattes | 7416585768192991 | - |
dc.identifier.lattes | 6644721827442957 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.