Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/15035
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Goiato, Marcelo Coelho | - |
dc.contributor.author | Garcia-Junior, Idelmo Rangel | - |
dc.contributor.author | Magro Filho, Osvaldo | - |
dc.contributor.author | Santos, Daniela Micheline dos | - |
dc.contributor.author | Pellizzer, Eduardo Piza | - |
dc.date.accessioned | 2013-09-30T18:29:53Z | - |
dc.date.accessioned | 2014-05-20T13:43:11Z | - |
dc.date.accessioned | 2016-10-25T16:57:48Z | - |
dc.date.available | 2013-09-30T18:29:53Z | - |
dc.date.available | 2014-05-20T13:43:11Z | - |
dc.date.available | 2016-10-25T16:57:48Z | - |
dc.date.issued | 2010-09-01 | - |
dc.identifier | http://dx.doi.org/10.1111/j.1741-2358.2009.00283.x | - |
dc.identifier.citation | Gerodontology. Malden: Wiley-blackwell, v. 27, n. 3, p. 243-247, 2010. | - |
dc.identifier.issn | 0734-0664 | - |
dc.identifier.uri | http://hdl.handle.net/11449/15035 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/15035 | - |
dc.description.abstract | This report presents the use of a dental implant with an anti-rotational attachment for the retention of a thumb prosthesis. A retention system was manufactured with an attachment (UCLA) screwed into the implant with a two-bar system that was cast in metallic silver palladium. A substructure made from heat-cured acrylic resin was joined to the retention system by clips to join the thumb to the finger (bar clip) in the cast with implant rejoinder. The silicone material, Silastic-MDX 44210, was used to achieve function and aesthetics. Following osseointegration, no skin problems were observed. Whilst the implant-retained digital prosthesis presented some motor limitations, it allowed the patient to return to entertainment and achieve social conviviality. | en |
dc.format.extent | 243-247 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | thumb prosthesis | en |
dc.subject | implant | en |
dc.subject | retention system | en |
dc.title | Implant-retained thumb prosthesis with anti-rotational attachment for a geriatric patient | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Dept Dent Mat & Prosthesis, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil | - |
dc.description.affiliation | UNESP, Dept Integrated Clin & Oral Surg, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Dept Dent Mat & Prosthesis, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Dept Integrated Clin & Oral Surg, Aracatuba Dent Sch, BR-16015050 Aracatuba, SP, Brazil | - |
dc.identifier.doi | 10.1111/j.1741-2358.2009.00283.x | - |
dc.identifier.wos | WOS:000281209300015 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Gerodontology | - |
dc.identifier.orcid | 0000-0002-3800-3050 | pt |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.