You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15037
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPellizzer, Eduardo Piza-
dc.contributor.authorTonella, Bianca Piccolotto-
dc.contributor.authorFerraco, Renato-
dc.contributor.authorFalcon-Antenucci, Rosse Mary-
dc.contributor.authorPerri de Carvalho, Paulo Sergio-
dc.contributor.authorRosifini Alves-Rezende, Maria Cristina-
dc.date.accessioned2013-09-30T18:30:07Z-
dc.date.accessioned2014-05-20T13:43:11Z-
dc.date.accessioned2016-10-25T16:57:48Z-
dc.date.available2013-09-30T18:30:07Z-
dc.date.available2014-05-20T13:43:11Z-
dc.date.available2016-10-25T16:57:48Z-
dc.date.issued2010-07-01-
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181e1b46e-
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 4, p. 1110-1113, 2010.-
dc.identifier.issn1049-2275-
dc.identifier.urihttp://hdl.handle.net/11449/15037-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15037-
dc.description.abstractThe aim of this study was to assess the stress distribution of the retention systems (screwed and cemented) for implant-supported fixed partial dentures by means of photoelastic method. Two models were made of photoelastic resin PL-2 with 2 implants (phi = 4.00 x 10 mm) located in the second premolar and molar region in each photoelastic model, varying the retention system (screwed and cemented). The implant-supported fixed partial dentures were standardized and made of Ni-Cr alloy. Axial and oblique (45 degrees) forces of 100 N were applied on the occlusal surface by means of a Universal Testing Machine (EMIC-DL 3000; Sao Jose dos Pinhais, Parana, Brazil). The results were observed and photographed in the field of a circular polariscope and qualitatively analyzed with the aid of computer software (Adobe Photoshop, San Jose, CA). The screw retention system presented the highest number of fringes when the loads were applied on the premolar, pontic, and molar and showed this behavior in all load applications, under axial and oblique loads. It was concluded that there was a better stress distribution and lower magnitude of stress on the cemented implant-supported dentures, under axial and oblique loads. Oblique load caused an increase in stress concentrations in all the models.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConexao Sistemas de Protese-
dc.format.extent1110-1113-
dc.language.isoeng-
dc.publisherLippincott Williams & Wilkins-
dc.sourceWeb of Science-
dc.subjectDental implanten
dc.subjectfixed partial denturesen
dc.subjectphotoelastic stress analysisen
dc.subjectscrew retaineden
dc.subjectcement retaineden
dc.titlePhotoelastic Stress Analysis in Screwed and Cemented Implant-Supported Dentures With External Hexagon Implantsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Surg & Integrated Clin, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Aracatuba Sch Dent, Dept Surg & Integrated Clin, São Paulo, Brazil-
dc.description.sponsorshipIdFAPESP: 07/55061-3-
dc.identifier.doi10.1097/SCS.0b013e3181e1b46e-
dc.identifier.wosWOS:000280149100038-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Craniofacial Surgery-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.