You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15136
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTonella, Bianca Piccolotto-
dc.contributor.authorPellizzer, Eduardo Piza-
dc.contributor.authorFerraco, Renato-
dc.contributor.authorFalcon-Antenucci, Rosse Mary-
dc.contributor.authorPerri de Carvalho, Paulo S.-
dc.contributor.authorGoiato, Marcelo Coelho-
dc.date.accessioned2013-09-30T18:29:42Z-
dc.date.accessioned2014-05-20T13:43:24Z-
dc.date.accessioned2016-10-25T16:58:00Z-
dc.date.available2013-09-30T18:29:42Z-
dc.date.available2014-05-20T13:43:24Z-
dc.date.available2016-10-25T16:58:00Z-
dc.date.issued2011-08-01-
dc.identifierhttp://dx.doi.org/10.1563/AAID-JOI-D-10-00044-
dc.identifier.citationJournal of Oral Implantology. Lawrence: Allen Press Inc, v. 37, n. 4, p. 401-410, 2011.-
dc.identifier.issn0160-6972-
dc.identifier.urihttp://hdl.handle.net/11449/15136-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15136-
dc.description.abstractThe aim of this study was to evaluate the stress distribution of different retention systems (screwed or cemented) associated with different prosthetic connections (external hexagon, internal hexagon, and Morse taper) in 3-unit implant-supported fixed partial dentures through photoelasticity. Six models were fabricated with photoelastic resin PL-2, and each model contained two implants of 4.0 x 10.0 mm. The models presented different retention systems (screwed and cemented) and different connections (external hexagon, internal hexagon, and Morse taper). The prostheses were standardized and fabricated in Ni-Cr alloy. A circular polariscope was used and axial and oblique (45) loads of 100 N were applied in a universal testing machine. The results were photographed and analyzed qualitatively with a graphic software (Adobe Photoshop). The screwed retention system exhibited higher number of fringes for both axial and oblique loadings. The internal hexagon implant presented better and lower stress distribution for both cemented and screwed prostheses. The oblique loading increased the number of fringes in all models tested. The cemented retention system presented better stress distribution. The internal hexagon implant was more favorable according to the biomechanical standpoint. The oblique load increased stress in all systems and connections tested.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent401-410-
dc.language.isoeng-
dc.publisherAllen Press Inc-
dc.sourceWeb of Science-
dc.subjectdental implantsen
dc.subjectfixed partial dentureen
dc.subjectimplant-supported fixed partial dentureen
dc.titlePhotoelastic Analysis of Cemented or Screwed Implant-Supported Prostheses With Different Prostheses Connectionsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Surg, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Surg, São Paulo, Brazil-
dc.description.sponsorshipIdFAPESP: 07/55061-3-
dc.identifier.doi10.1563/AAID-JOI-D-10-00044-
dc.identifier.wosWOS:000294311700004-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Oral Implantology-
dc.identifier.orcid0000-0002-3800-3050pt
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.