You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15176
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBarbosa, Débora de Barros-
dc.contributor.authorde Souza, Raphael Freitas-
dc.contributor.authorPero, Ana Carolina-
dc.contributor.authorMarra, Julie-
dc.contributor.authorCompagnoni, Marco Antonio-
dc.date.accessioned2014-02-26T17:02:28Z-
dc.date.accessioned2014-05-20T13:43:29Z-
dc.date.available2014-02-26T17:02:28Z-
dc.date.available2014-05-20T13:43:29Z-
dc.date.issued2007-09-01-
dc.identifierhttp://dx.doi.org/10.1590/S1678-77572007000500010-
dc.identifier.citationJournal of Applied Oral Science. Bauru-sp: Univ São Paulo Fac Odontologia Bauru, v. 15, n. 5, p. 424-428, 2007.-
dc.identifier.issn1678-7757-
dc.identifier.urihttp://hdl.handle.net/11449/15176-
dc.description.abstractDespite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Classico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acrylic (Jet) resins were used. Five groups were established, according to polymerization cycles: A, B and C (Onda-Cryl, short cycle - 500W/3 min, long - 90W/13 min + 500W/90 see, and manufacturing microwave cycle - 320W/3 min + OW/3 min + 720W/3 min); T(Classico, water bath cycle - 74 degrees C/9h) and Q (Jet, press chamber cycle - 50 degrees C/15 min at 2 bar). Ten specimens (65 x 10 x 3.3 mm) were prepared for each cycle. The flexural strength of the five groups was measured using a three-point bending test at a cross-head speed of 5 mm/min. Flexural strength values were analyzed by one-way ANOVA and the Tukey's test was performed to identify the groups that were significantly different at 5% level. The microwave-polymerized groups showed the highest means (p<0.05) for flexural strength (MPa) (A = 106.97 +/- 5.31; B = 107.57 +/- 3.99; C = 109.63 +/- 5.19), and there were no significant differences among them. The heat-polymerized group (T) showed the lowest flexural strength means (84.40 +/- 1.68), and differ significantly from all groups. The specimens of a microwavable denture base resin could be polymerized by different microwave cycles without risk of decreasing the flexural strength.en
dc.format.extent424-428-
dc.language.isoeng-
dc.publisherUniversidade de São Paulo (USP), Faculdade de Odontologia de Bauru-
dc.sourceWeb of Science-
dc.subjectdenturespt
dc.subjectacrylic resinspt
dc.subjectmicrowavespt
dc.subjectphysical propertiespt
dc.subjectstrengthpt
dc.titleFlexural strength of acrylic resins polymerized by different cyclesen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUNESP, Dent Sch Aracatuba, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil-
dc.description.affiliationUSP, Dent Sch Ribeirao Preto, Dept Dent Mat & Prosthodont, Ribeirao Preto, SP, Brazil-
dc.description.affiliationUnespUNESP, Dent Sch Aracatuba, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil-
dc.identifier.doi10.1590/S1678-77572007000500010-
dc.identifier.scieloS1678-77572007000500010-
dc.identifier.wosWOS:000256794600009-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileWOS000256794600009.pdf-
dc.relation.ispartofJournal of Applied Oral Science-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.