You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15201
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAssunção, Wirley Goncalves-
dc.contributor.authorRicardo Barao, Valentim Adelino-
dc.contributor.authorTabata, Lucas Fernando-
dc.contributor.authorSousa, Edson Antonio Capello-
dc.contributor.authorGomes, Erica Alves-
dc.contributor.authorDelben, Juliana Aparecida-
dc.date.accessioned2013-09-30T18:10:35Z-
dc.date.accessioned2014-05-20T13:43:32Z-
dc.date.accessioned2016-10-25T16:58:06Z-
dc.date.available2013-09-30T18:10:35Z-
dc.date.available2014-05-20T13:43:32Z-
dc.date.available2016-10-25T16:58:06Z-
dc.date.issued2009-12-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2008.00268.x-
dc.identifier.citationGerodontology. Malden: Wiley-blackwell Publishing, Inc, v. 26, n. 4, p. 273-281, 2009.-
dc.identifier.issn0734-0664-
dc.identifier.urihttp://hdl.handle.net/11449/15201-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15201-
dc.description.abstractComparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distributionBackground:The effect of different mucosa characteristics on stress distribution of complete dentures and overdentures remains unknown.Objective:The aim of this study was to evaluate the effect of different mucosa thickness and resiliency on the stress distribution of complete dentures and implant-retained overdentures using a two-dimensional finite element analysis.Material and methods:Representative models of the edentulous mandible were constructed on AutoCAD software according to the groups' characteristics. In group CD, a model of the edentulous mandible supporting a complete denture was obtained while in group IO, a model of edentulous mandible supporting an overdenture over two unsplinted implants with an o' ring system was constructed. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) corresponding to the resiliencies hard, resilient and soft respectively. Evaluation was performed on Ansys software with 100N vertical load applied on central incisor teeth. The principal stress was used as analysis criteria.Results:Group IO showed higher stress values than group CD regardless of mucosal thickness and resiliency. Stress decreased at the supporting tissues in both groups as the thickness and resiliency of mucosa increased. In relation to the supporting tissues, cortical bone showed the highest stress values.Conclusion:It was concluded that the use of an attachment system increases stress values and the thickness and resiliency of mucosa influence more on these values.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent273-281-
dc.language.isoeng-
dc.publisherWiley-Blackwell Publishing, Inc-
dc.sourceWeb of Science-
dc.subjectdental implantsen
dc.subjectcomplete dentureen
dc.subjectoverdentureen
dc.subjectattachmenten
dc.subjectfinite element analysisen
dc.subjectbiomechanicsen
dc.titleComparison between complete denture and implant-retained overdenture: effect of different mucosa thickness and resiliency on stress distributionen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Aracatuba, SP, Brazil-
dc.description.affiliationSão Paulo State Univ, Bauru Engn Sch, Dept Mech Engn, UNESP, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, UNESP, BR-16015050 Aracatuba, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Bauru Engn Sch, Dept Mech Engn, UNESP, São Paulo, Brazil-
dc.description.sponsorshipIdFAPESP: 06/52230-6-
dc.description.sponsorshipIdFAPESP: 06/59770-6-
dc.identifier.doi10.1111/j.1741-2358.2008.00268.x-
dc.identifier.wosWOS:000271940300006-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofGerodontology-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.