You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15204
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRicardo Barao, Valentim Adelino-
dc.contributor.authorAssunção, Wirley Goncalves-
dc.contributor.authorTabata, Lucas Fernando-
dc.contributor.authorSousa, Edson Antonio Capello-
dc.contributor.authorRocha, Eduardo Passos-
dc.date.accessioned2013-09-30T18:10:32Z-
dc.date.accessioned2014-05-20T13:43:33Z-
dc.date.accessioned2016-10-25T16:58:06Z-
dc.date.available2013-09-30T18:10:32Z-
dc.date.available2014-05-20T13:43:33Z-
dc.date.available2016-10-25T16:58:06Z-
dc.date.issued2008-11-01-
dc.identifierhttp://dx.doi.org/10.1016/j.cmpb.2008.07.009-
dc.identifier.citationComputer Methods and Programs In Biomedicine. Clare: Elsevier B.V., v. 92, n. 2, p. 213-223, 2008.-
dc.identifier.issn0169-2607-
dc.identifier.urihttp://hdl.handle.net/11449/15204-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15204-
dc.description.abstractThe study aimed to evaluate the effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures using a two-dimensional finite element analysis. Models were used in order to simulate two situations. In group A, model represented an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system while in group B, model simulated an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system associated with two-distally placed o'ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) in the resiliencies: hard, resilient and soft, respectively Evaluation was performed on Ansys software. Group A showed higher stress values regardless of the mucosa characteristics. Overall, stress decreased at the supporting tissues as mucosa. thickness and resiliency increased. Regarding supporting tissues, cortical bone showed the highest stress values. The use of bar-clip attachment system with distally placed o'ring attachment design optimized the stress distribution. (C) 2008 Elsevier B.V. All rights reserved.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent213-223-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectDental implantsen
dc.subjectOverdentureen
dc.subjectAttachmenten
dc.subjectFinite element analysisen
dc.subjectBiomechanicsen
dc.titleEffect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEAen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil-
dc.description.affiliationUniv Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 São Paulo, Brazil-
dc.description.sponsorshipIdFAPESP: 06/52230-6-
dc.description.sponsorshipIdFAPESP: 06/59770-6-
dc.identifier.doi10.1016/j.cmpb.2008.07.009-
dc.identifier.wosWOS:000260919300007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofComputer Methods and Programs In Biomedicine-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.